neqsim-depressurization-mdmt
Skill167 starsChanged 7 months agoApache-2.0View on GitHub
Emergency depressurization (blowdown) per API 521 and MDMT assessment per ASME UCS-66 / API 579 / EN 13445 with a VU-flash transient model. USE WHEN: sizing a blowdown valve, producing a P-vs-time curve under fire or depressurization, checking MDMT against blowdown end-temperature, supplying relief/flare source terms, or separating blowdown from trapped-liquid rupture. Anchors on DepressurizationSimulator and MDMTCalculator.
In this repository140 other files it gives its agents.
- AGENTS.mdAGENTS.md
- CLAUDE.mdCLAUDE.md
- .github/copilot-instructions.mdCopilot instructions
- analyze-convergenceSkill
- analyze-gibbs-convergenceSkill
- book-creationSkill
- design-flash-benchmarkSkill
- design-reactor-benchmarkSkill
- figure-discussionSkill
- generate-publication-figuresSkill
- journal-formattingSkill
- neqsim-acid-gas-treatingSkill
- neqsim-advanced-control-mpc-and-virtual-sensingSkill
- neqsim-agent-handoffSkill
- neqsim-agentic-process-optimizationSkill
- neqsim-api-patternsSkill
- neqsim-autonomous-investigationSkill
- neqsim-capability-mapSkill
- neqsim-capacity-and-utilization-analysisSkill
- neqsim-capacity-increase-screeningSkill
- neqsim-ccs-hydrogenSkill
- neqsim-code-healthSkill
- neqsim-code-hygieneSkill
- neqsim-code-reviewSkill
- neqsim-column-internals-and-rate-basedSkill
- neqsim-compressor-antisurge-recycleSkill
- neqsim-consequence-analysisSkill
- neqsim-continuous-task-improvementSkill
- neqsim-controllability-operabilitySkill
- neqsim-cooling-waterSkill
- neqsim-cpa-water-boundariesSkill
- neqsim-distillation-designSkill
- neqsim-document-intelligence-extractionSkill
- neqsim-dynamic-equipment-implementationSkill
- neqsim-dynamic-simulationSkill
- neqsim-electrolyte-systemsSkill
- neqsim-emulsion-separationSkill
- neqsim-energy-systems-and-electrificationSkill
- neqsim-engineering-design-packageSkill
- neqsim-eos-regressionSkill
- neqsim-equipment-cost-estimationSkill
- neqsim-exploration-strategy-selectionSkill
- neqsim-field-developmentSkill
- neqsim-field-economicsSkill
- neqsim-firewater-deluge-designSkill
- neqsim-flow-accelerated-corrosionSkill
- neqsim-flow-assuranceSkill
- neqsim-flow-assurance-study-reportSkill
- neqsim-forward-separator-trainSkill
- neqsim-future-operation-studySkill
- neqsim-hazid-fmea-eta-ftaSkill
- neqsim-heat-integrationSkill
- neqsim-hydrogen-productionSkill
- neqsim-input-validationSkill
- neqsim-integrated-production-and-lifecycleSkill
- neqsim-in-writingSkill
- neqsim-java8-rulesSkill
- neqsim-jurisdiction-regulatory-basisSkill
- neqsim-literature-searchSkill
- neqsim-lng-liquefactionSkill
- The first 60 shown.
The file
We split this skill into the rules it gives an agent
7 rules. About 0 are common, 6 are distinctive, and 1 is very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈6
Distinctive · estimate
This author's own choices. Worth a look.
1
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 100
Start from a target such as 50 % of design pressure in 15 min (API 521), 7 bar in 15 min, or the relevant company/project criterion from …
- Distinctive: line 103
Verify the *minimum* T(t) is above the vessel MDMT.
- Distinctive: line 216
Remove at most about a quarter of the vapour phase per step.
- Distinctive: line 244
When several vessels blow down simultaneously into one flare/disposal header, the
- Very specific: line 267
Use addSourceResult(...) with a pre-computed DepressurizationResult to avoid re-running the (slow) VU-flash transient for vessels already …
- Distinctive: line 364
When a single-temperature lumped model is not enough — gas/liquid temperature bifurcation in a fire, transient PSV sizing conservatism, …
- Distinctive: line 436
Make sure the simulator's flow model uses choked-flow correlations until P_vessel / P_back < 1/r_critical.
≈ “Common” is an estimate: at least 1 in 5 of the 350,495 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
NeqSim Depressurization & MDMT Skill
Transient blowdown / depressurization for inventory release on fire or controlled emergency, plus the minimum design metal temperature (MDMT) check that drives material selection. The two are linked: blowdown end-temperatures (often −80 to −120 °C for hydrocarbon gas) usually drive MDMT, which in turn drives whether LTCS, low-temperature carbon-Mn, 3.5 % Ni or 9 % Ni / 304L is required.
When to Use
- Sizing a blowdown / depressurization valve to reach 50 % pressure in 15 min (API 521 §5.20 fire case) or 7 bar in some operator standards
- Generating P(t), T(t), m(t) curves for the relief / flare load case
- Screening MDMT against end-of-blowdown vessel-wall temperature
- Producing source terms for the flare network (
neqsim-relief-flare-network) - Distinguishing depressurization cases from blocked-in liquid fire rupture cases,
where
neqsim-trapped-liquid-fire-ruptureis the primary workflow
Distinct from neqsim-relief-flare-network (steady-state PSV sizing) and
neqsim-dynamic-simulation (continuous-process transients) — this skill is the
specific blowdown + MDMT pair.
Standards
- API 521 7th ed. — Pressure-relieving and depressuring systems (§5.20 blowdown)
- API STD 520 — PSV sizing, used for choke check at the BDV
- ASME UCS-66 / UCS-66.1 — MDMT impact-test exemption curves (carbon steel)
- ASME UHA-51 — austenitic stainless steel low-temperature service
- API 579 / FFS-1 §3 — fitness-for-service, MDMT for in-service vessels
- EN 13445-2 Annex B — European MDMT and impact-test approach
- NORSOK L-002 — piping system design (low-temperature operation)
Method 1 — Blowdown Simulation (VU-flash)
import neqsim.thermo.system.SystemSrkEos;
import neqsim.thermo.system.SystemInterface;
import neqsim.process.safety.depressurization.DepressurizationSimulator;
SystemInterface gas = new SystemSrkEos(273.15 + 50.0, 100.0);
gas.addComponent("methane", 0.92);
gas.addComponent("ethane", 0.05);
gas.addComponent("propane", 0.03);
gas.setMixingRule("classic");
gas.setTotalNumberOfMoles(5000.0); // mol — representative of vessel inventory
DepressurizationSimulator sim = new DepressurizationSimulator(gas);
sim.setVesselVolume(50.0); // m³
sim.setOrificeArea(5.0e-4); // m² — BDV equivalent area
sim.setBackPressure(1.5); // bara — flare KO drum
sim.setHeatInput(0.0); // adiabatic; > 0 for fire case
sim.run(900.0, 1.0); // 15 min, 1 s timestep
double[] t = sim.timeSeries();
double[] p = sim.pressureSeries();
double[] T = sim.temperatureSeries();
double[] m = sim.massFlowSeries();
double pEnd = p[p.length - 1];
double tEnd = T[T.length - 1];
double t50 = sim.timeToPressure(50.0); // s, time to 50 barThe simulator uses the U–V flash (ops.VUflash(V, U)) at every step — internal
energy decreases by h_out · ṁ · Δt and volume is held constant by the vessel,
so each step is a fully consistent thermodynamic state. Joule-Thomson cooling
across the BDV is captured via an isenthalpic flash to the back pressure for the
exit-temperature output.
Fire case
sim.setHeatInput(60_000.0); // W — API 521 fire heat inputAPI 521 fire heat input on uninsulated vessels:
Q = 43.2 · F · A^0.82 [W]
with environment factor F (= 1.0 for un-insulated, 0.30 for fireproof insulation, 0.075 for water-spray) and wetted area A in m². The simulator accepts the value directly so any of the API 521, NFPA 30 or NORSOK correlations can be used upstream.
Method 2 — BDV Sizing Iteration
Typical workflow:
- Start from a target such as 50 % of design pressure in 15 min (API 521), 7 bar in 15 min, or the relevant company/project criterion from the private basis.
- Guess BDV
Cd · A, runsim.run(...), readsim.timeToPressure(target). - Iterate area until target is met without choking the flare header.
- Verify the minimum T(t) is above the vessel MDMT.
A reference iteration loop is available as
DepressurizationSimulator.sizeForTargetPressure(targetBar, targetTimeS).
Method 3 — MDMT Assessment
import neqsim.process.safety.mdmt.MDMTCalculator;
MDMTCalculator mdmt = new MDMTCalculator();
mdmt.setMaterial("SA-516-70N"); // normalised CMn, common for CS vessels
mdmt.setThicknessMM(50.0);
mdmt.setStressRatio(0.35); // operating / allowable stress ratio
double mdmtC = mdmt.computeUCS66(); // °C — ASME UCS-66 + UCS-66.1 reductionThe calculator implements:
- UCS-66 Curve A / B / C / D lookup vs material specification
- UCS-66.1 stress-ratio reduction (lower stress → lower MDMT)
- API 579 §3 Fitness-for-Service path for in-service vessels with crack reassessment factors
- EN 13445-2 Annex B alternative if requested
Pass / fail check
double bdvEndTemp = sim.minTemperatureC(); // °C from blowdown sim
boolean acceptable = bdvEndTemp >= mdmtC;
if (!acceptable) {
// Either: thicker vessel, lower stress ratio, LTCS / 3.5%Ni material,
// slower BDV, or accept impact testing per UG-84.
}Many company practices add a 5-10 °C margin between blowdown end-temperature and MDMT. Record the actual project or operator margin in the private task basis instead of hard-coding it in public guidance.
Method 4 — Source Term to Flare Network
double[] mdot = sim.massFlowSeries();
double[] T = sim.temperatureSeries();
double[] P = sim.pressureSeries();
// Pass to ReliefValveSizing peak-load aggregator or to
// FlareStack.estimateRadiationHeatFlux at peak ṁ.
double mdotPeak = sim.peakMassFlow();This is the standard handoff between the depressurization model and the flare
network sizing skill (neqsim-relief-flare-network).
Method 4b — Separators with Live Liquid: Vapour-Only Withdrawal (MANDATORY CHECK)
A blowdown valve is mounted on top of the vessel, so a separator, scrubber or knock-out drum holding live liquid discharges vapour while the liquid flashes and feeds more vapour into the release. Discharging the bulk composition instead drains heavy liquid through the orifice: it understates the flare load and overstates the cooling, and the mass balance still closes, so nothing fails.
DepressurizationSimulator handles this from NeqSim 3.20 onward:
import neqsim.process.safety.depressurization.DepressurizationSimulator.WithdrawalMode;
DepressurizationSimulator sim = new DepressurizationSimulator(fluid, V, dOrifice, Cd, pBack);
sim.setWithdrawalMode(WithdrawalMode.AUTO); // default
DepressurizationResult res = sim.run();
boolean twoPhase = res.vapourWithdrawalUsed; // true when a step discharged vapour- AUTO (default) discharges vapour whenever the inventory is multiphase and is identical to BULK for a single-phase inventory, so a dry-gas segment is unaffected.
- VAPOUR forces it; BULK restores the legacy behaviour for comparison.
- On a real first-stage separator the flash gas from the oil holdup can be a third of the
total flare load. Operator flare reports often quote
vapour fraction = 1.00for such a segment, which means the liquid contribution is not in the approved basis either — say so rather than silently matching their number. run()removes moles from the fluid you passed in (no clone). Record the component moles beforerun(); start minus end is the per-component composition sent to flare, which is what flare CO2 needs: $m_{CO_2} = 44.01,(\eta \sum_i n_{C,i} N_i + N_{CO_2})$ with $\eta \approx 0.98$ combustion efficiency. Clone first if you need the start state later.- A pip-installed
neqsimolder than 3.20 has nosetWithdrawalMode(AttributeError); load the workspace classes throughdevtools/neqsim_dev_setup.pyinstead.
Cross-check the transient against a decomposed inventory
For a deliverable, back the transient with a path-independent inventory calculation: flare load = (gas-space inventory − gas remaining at the flare back pressure) + (vapour formed when the liquid holdup is flashed to the back pressure). Each term is a single TP flash of a stream that exists in the process documentation, so every number is traceable. Expect the transient to give slightly more, because continuous stripping of light ends drives further vaporisation.
If you write your own withdrawal loop, three traps
// TRAP 1 — phase identification. Below roughly 20 bara NeqSim may label the OIL phase
// GAS for a rich hydrocarbon mixture. Selecting the vapour with getPhase(i).getType() then
// strips LIQUID out of the vessel, and the mass balance still closes, so nothing throws.
// Use the helper, which selects by lowest density and returns -1 when no phase is vapour:
int iVap = DepressurizationSimulator.vapourPhaseIndex(fluid);
// TRAP 2 — assert the removed stream is actually vapour. A hydrocarbon blowdown stream
// should stay well under ~45 g/mol. Check it EVERY step; this is what catches trap 1.
// TRAP 3 — component moles. phase.getComponent(n).getNumberOfMolesInPhase() is not
// reliably phase-local. Use the phase total against the phase mole fraction:
double dnTotal = fraction * fluid.getPhase(iVap).getNumberOfMolesInPhase();
double dnComponent = dnTotal * fluid.getPhase(iVap).getComponent(name).getx();Remove at most about a quarter of the vapour phase per step. Emptying most of the vapour space in one step makes the constant-volume flash swing, because the liquid flashes back to refill it.
Pseudo-component naming: addTBPfraction("C6gas", ...) is stored as C6gas_PC. Never put
+ in a TBP name, and resolve the internal name from getComponentNames() by prefix before
calling addComponent(name, -moles).
Report both CO2 numbers
For an emissions answer, separate the CO2 already in the gas (typically 1–3 mol%, so a few hundred kg) from the CO2 produced by burning the release (roughly 2.7 kg CO2 per kg hydrocarbon, so tonnes). The combustion term is two orders of magnitude larger and is the one that goes into emission reporting. State the assumed flare combustion efficiency, and give the CO2-equivalent of the unburned methane for the failed-ignition case (GWP-100 = 28, IPCC AR5) — that is typically ~5x the climate effect of a successful flaring.
Time is rarely the binding constraint — temperature is
API 521 §5.20 (half pressure in 15 min) is usually met with a large margin on a correctly sized BDV. What actually governs is auto-refrigeration against the vessel MDMT and the downstream pipe class design temperature. Always report the minimum temperature next to both limits, and recommend throttling a planned depressurisation through the pressure control valve down to a moderate pressure before opening the BDV, so the fast cold excursion is reserved for genuine emergency depressurisation.
Method 5 — Coupled Multi-Vessel Blowdown to a Shared Header (API 521 §7)
When several vessels blow down simultaneously into one flare/disposal header, the
combined load — not any single vessel — sizes the header. MultiVesselBlowdownStudy
superimposes each source on a common time grid and checks the header Mach at the peak.
import neqsim.process.safety.depressurization.MultiVesselBlowdownStudy;
import neqsim.process.safety.depressurization.MultiVesselBlowdownStudy.MultiVesselBlowdownResult;
MultiVesselBlowdownResult res = new MultiVesselBlowdownStudy()
.addSource("V-100", bdvSim100) // configured DepressurizationSimulator
.addSource("V-200", bdvSim200)
.addSourceResult("V-300", precomputed) // or a pre-computed DepressurizationResult
.setHeader(0.6, 1.5, 288.15, 0.020, 1.30) // D[m], P[bara], T[K], M[kg/mol], gamma
.setMaxAllowableMach(0.70) // API 521 §7 / NORSOK P-002
.run();
double peak = res.getPeakTotalMassFlowKgPerS();
double tPeak = res.getPeakTimeS();
double mach = res.getHeaderMach();
boolean okMach = res.isHeaderMachAcceptable();
String report = res.summary();Use addSourceResult(...) with a pre-computed DepressurizationResult to avoid
re-running the (slow) VU-flash transient for vessels already simulated.
Method 5b — Governed STID/TR2000 Dynamic Blowdown + Flare Handoff
For agentic engineering studies that start from STID/P&ID drawings, line lists, equipment lists, and TR2000 pipe/valve/material evidence, use the governed data source and runner instead of stitching transient notebooks together by hand.
Key classes:
LineEquipmentListEvidence— reviewed line-list and equipment-list rows used to build the dynamic model.DynamicBlowdownFlareStudyDataSource— source-traceable package with oneBlowdownSourceper protected equipment item plus header, flare, PSV, fire, topology, and evidence status.DynamicBlowdownFlareStudyRunner— runsDepressurizationSimulator, aggregates loads withMultiVesselBlowdownStudy, sizes PSV orifices throughReliefValveSizing, and estimates peak/cumulative flare heat, emissions, radiation distance, and capacity utilization.DynamicBlowdownFlareStudyHandoff— versioned JSON package containingdynamic_blowdown_flare_result.v1anddynamic_blowdown_flare_load_handoff.v1.
LineEquipmentListEvidence lineEq = LineEquipmentListEvidence.builder("line-eq-001")
.lineListReviewed(true)
.equipmentListReviewed(true)
.addEquipment("V-100", "separator", 50.0, 85.0, 70.0, 313.15)
.addLine("BD-100", "V-100", "FLARE-HDR", 6.0, 0.154, 0.007, 45.0, "DD100", "API 5L X52")
.build();
DynamicBlowdownFlareStudyDataSource.BlowdownSource source =
DynamicBlowdownFlareStudyDataSource.BlowdownSource.builder("V-100", gas)
.equipmentTag("V-100")
.vesselVolumeM3(50.0)
.orificeDiameterM(0.035)
.dischargeCoefficient(0.72)
.backPressureBara(1.5)
.api521FireCase(120.0, true, true)
.psvBasis(85.0, 0.21, false, false)
.build();
DynamicBlowdownFlareStudyDataSource data = DynamicBlowdownFlareStudyDataSource.builder("BD-FLARE-001")
.lineEquipmentListEvidence(lineEq)
.addSource(source)
.flareHeader(0.6, 1.5, 288.15, 0.020, 1.30)
.flareGeometry(0.8, 50.0, 0.20)
.stidDiagramReviewed(true)
.lineEquipmentListsReviewed(true)
.vesselInventoryReviewed(true)
.valveSizingBasisReviewed(true)
.psvBasisReviewed(true)
.flareSystemBasisReviewed(true)
.fireCaseReviewed(true)
.standardsReviewed(false)
.build();
DynamicBlowdownFlareStudyHandoff handoff = DynamicBlowdownFlareStudyRunner.builder()
.timeStepSeconds(1.0)
.maxTimeSeconds(900.0)
.build()
.run(data);Readiness semantics mirror the pipe-fire runner: missing source fluid, volume, BDV/orifice diameter, discharge coefficient, or flare backpressure blocks the calculation; missing reviewed topology, TR2000, PSV, fire, or flare capacity evidence keeps the result at screening level.
Method 6 — ESD Response-Time Budget (NOG 070 / IEC 61511)
The blowdown / isolation only mitigates the relief load if the ESD valve actually
closes in time. EsdResponseTimeSimulator sums the SIF loop contributions and
compares against the allowable budget.
import neqsim.process.safety.esd.EsdResponseTimeSimulator;
import neqsim.process.safety.esd.EsdResponseTimeSimulator.EsdResponseTimeResult;
EsdResponseTimeResult esd = new EsdResponseTimeSimulator()
.setSifTag("SIF-2001 ESDV closure")
.addDetection("PT-2001 detection", 2.0) // s
.addLogic("Logic solver scan + 2oo3 vote", 0.5)
.addValve("ESDV-2001 close", 1.0, 18.0) // solenoid delay, valve stroke
.setAllowableResponseTimeS(45.0)
.evaluate();
double total = esd.getTotalResponseTimeS();
double margin = esd.getMarginS();
boolean ok = esd.isWithinBudget();This is a budgeting tool — it does not replace certified SIS proof testing or
FAT/SAT. Pair with neqsim-process-safety for the SIL determination of the SIF.
Method 7 — Vessel Thermomechanical Safety Models
When a single-temperature lumped model is not enough — gas/liquid temperature
bifurcation in a fire, transient PSV sizing conservatism, fast filling, cryogenic
boil-off, through-wall thermal lag, or wall rupture — use the dedicated
thermomechanical classes. They reproduce the application cases of Andreasen
(2026), J. Loss Prev. Process Ind. 103, 106088, and are covered by committed
regression tests. See docs/safety/vessel_thermomechanical_safety.md for the
full guide.
// Two-temperature (non-equilibrium) fire blowdown — gas superheats, liquid stays cold
import neqsim.process.safety.depressurization.NonEquilibriumBlowdownModel;
import neqsim.process.safety.depressurization.NonEquilibriumBlowdownModel.NemResult;
NonEquilibriumBlowdownModel nem =
new NonEquilibriumBlowdownModel(fluid, 10.0, 0.025, 0.72, 1.0e5);
nem.setFireExposure(0.9, 1100.0, 30.0, 25.0).setWall(8000.0, 470.0);
nem.setTimeStep(1.0).setMaxTime(600.0).setStopPressure(1.5e5);
NemResult bd = nem.run();
double bifurcationK = bd.maxTemperatureBifurcationK;
// Dynamic PSV sizing — quantify API 521 steady-state oversizing (§4.1)
import neqsim.process.safety.depressurization.DynamicPsvSizingStudy;
DynamicPsvSizingStudy.SizingComparison cmp =
new DynamicPsvSizingStudy(gas, 1.0, 150000.0, 11.0e5, 0.21, 1.0e5)
.setBlowdownFraction(0.1).setDischargeCoefficient(0.975).run();
double oversizing = cmp.oversizingRatio; // > 1 => steady-state conservative
// Fast filling of a Type IV hydrogen cylinder — liner temperature limits (§4.2)
import neqsim.process.safety.depressurization.VesselFillingSimulator;
VesselFillingSimulator.VesselFillingResult fill =
new VesselFillingSimulator(h2, 0.06)
.setInletConditions(283.15, 360.0, 0.015)
.setTargetPressure(351.0)
.setLinerTemperatureLimits(233.15, 338.15)
.setTimeStep(1.0).setMaxTime(4000.0).run();
boolean linerOk = fill.linerLimitsMet;
// Cryogenic boil-off vs insulation thickness (§4.3)
import neqsim.process.util.heattransfer.BoilOffCalculator;
double boilOff = new BoilOffCalculator()
.setSurfaceArea(150.0).setOuterFilmCoefficient(10.0)
.setInsulationConductivity(0.025).setAmbientTemperatureK(288.15)
.setFluidTemperatureK(253.15).setLatentHeat(320000.0)
.boilOffRateKgPerH(0.30);
// Fire/blowdown wall rupture vs temperature-derated strength (§4.4)
import neqsim.process.safety.rupture.VesselRuptureAnalyzer;
import neqsim.process.safety.rupture.MaterialStrengthCurve;
MaterialStrengthCurve steel = MaterialStrengthCurve.carbonSteel("CS", 245.0e6, 415.0e6);
VesselRuptureAnalyzer.VesselRuptureResult rup =
new VesselRuptureAnalyzer(0.5, 0.012, steel).analyze(timeS, pressurePa, metalTempK);
boolean ruptured = rup.ruptured; // bare LPG vessel ruptures in minutes; PFP prevents itSupporting classes: CompositeWallConduction (1D transient multi-layer wall,
Crank-Nicolson; use the static biotNumber(...) helper — lumped is fine for
Bi < 0.1), VesselHeatTransferCorrelations (Woodfield filling Nusselt,
Rohsenow nucleate boiling), and BlockedOutletOverpressureAnalyzer (blocked-in
charging overpressure with relief-demand flag).
Common Pitfalls
- Adiabatic vs fire case — running adiabatic blowdown gives the coldest end-temperature (worst for MDMT). Running fire case gives the highest peak flow (worst for flare network). Both must be checked separately.
- Single component vs multi-component — MDMT is driven by the end-of-blowdown temperature, which depends on JT coefficient and is sensitive to ethane / propane content. Always use a representative composition, not a pure-methane simplification.
- Ignoring liquid level — vessels with liquid have huge thermal mass; the gas phase cools quickly while the liquid holds temperature. The simulator handles two-phase systems automatically.
- Choked vs sub-critical flow — the BDV chokes for most of the blowdown. Make sure the simulator's flow model uses choked-flow correlations until P_vessel / P_back < 1/r_critical.
- Stress ratio = 1 — using 1.0 for stress ratio gives the most conservative MDMT. Operating-pressure stress ratio (0.30–0.40) usually relaxes MDMT by 10–30 °C.
Verification Tests
./mvnw test -Dtest=DepressurizationSimulatorTest,MDMTCalculatorTest,MultiVesselBlowdownStudyTest,EsdResponseTimeSimulatorTest
./mvnw test -Dtest=DynamicPsvSizingStudyTest,VesselFillingSimulatorTest,VesselRuptureAnalyzerTest,BoilOffCalculatorTestSee Also
neqsim-relief-flare-network— PSV sizing, flare radiation, header back-pressureneqsim-firewater-deluge-design— blowdown is the primary barrier for a pressurised inventory; compare the blowdown time against the time exposed steel survives before deciding how much fire water is worth addingneqsim-trapped-liquid-fire-rupture— blocked-in liquid thermal expansion, PFP demand, and rupture source-term handoffneqsim-dynamic-simulation— continuous-process transients with controllersneqsim-consequence-analysis— what happens after the released gas ignitesneqsim-flow-assurance— JT cooling and hydrate formation in blowdownneqsim-process-safety— LOPA / SIL for the blowdown SIF (BDV-SIF)
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.