Model fresh-water and seawater cooling in NeqSim heat exchangers, reference IAPWS utility properties, coolant flow and pump duty, fixed-UA or outlet-temperature cases and seasonal/fouling checks. Use for water-cooled gas coolers, closed cooling water, seawater exchangers and cooling-water utility sizing.

The file

We split this skill into the rules it gives an agent

5 rules. About 0 are common, 2 are distinctive, and 3 are very specific to this project.

  • ≈0

    Common · estimate

    Many files like this have a rule of this kind.

  • ≈2

    Distinctive · estimate

    This author's own choices. Worth a look.

  • 3

    Very specific

    Tied to their project's names, files or tools. Probably skip.

  • Common
  • Distinctive
  • Very specific
  1. Very specific:

    Read docs/process/equipment/reference_cooling_water.md before constructing the model.

    line 9
  2. Very specific:

    Keep the process-side EOS and transport models.

    line 26
  3. Distinctive:

    Use IAPWS-IF97 for fresh water.

    line 38
  4. Distinctive:

    Check terminal approaches, positive flow and capacity ordering.

    line 64
  5. Very specific:

    Test nearby seasonal T/S/flow, repeated runs, changed salinity and fouling cases.

    line 72

≈ “Common” is an estimate: at least 1 in 5 of the 350,495 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.

Keep what fits and drop the rest. Your version, ready for your agents.
Files
SKILL.md

Reference cooling water and seawater

Read docs/process/equipment/reference_cooling_water.md before constructing the model. Verify the source/JAR version and APIs; a newly published source API may not exist in the installed release. Use @process-model for the two-stream flowsheet and @utility-design for plant supply/pumping. Coordinate with @thermo-fluid when composition or property validity is uncertain.

Select the model

NeedRoute
Pure-water utility streamneqsim.thermo.system.SystemWaterIF97
Fixed-salinity standard-composition seawater utilityneqsim.thermo.system.SystemSeawater
Both inlet flows known; solve duty/return temperaturesneqsim.process.equipment.heatexchanger.HeatExchanger
Process outlet target; size utility demand from supply/return temperaturesneqsim.process.equipment.heatexchanger.WaterCooler
Cooling duty roll-up, actual volume and pump powerneqsim.process.equipment.heatexchanger.CoolingWaterSystem
Glycol, arbitrary brine, gas dissolution, pH, scale, dilution or salt mixingUse the appropriate mixture/electrolyte workflow; the bulk utility model cannot track salt species

Keep the process-side EOS and transport models. A WATER physical-property enum on an SRK/PR/CPA system does not select reference-water enthalpy. Reference-system constructors already add one nominal component; set total flow, without adding salts or setting an EOS mixing rule. Use the tested Java guide through the verified Java/JPype interface; do not invent a curated MCP execution route.

Define and execute the case

  1. Record process composition, model/mixing rule, flow, T/P and duty or outlet target. Record utility supply T/P, return-temperature limit, mass flow or unknown demand, salinity basis and seasonal range. Keep bara separate from barg and hydraulic pressure drop.
  2. Use IAPWS-IF97 for fresh water. For seawater, set Reference-Composition Salinity in g/kg solution. Practical salinity 35 corresponds to 35.16504 g/kg for Reference Composition. Do not substitute g/kg solvent or an arbitrary NaCl concentration. Treat missing salinity as a stated assumption.
  3. For two streams, create independent fluids and named supply/return streams; preserve them in the canonical ProcessSystem. The fixed-salinity model carries bulk-solution mass using nominal water moles; use mass-based results.
  4. For WaterCooler, use setOutletTemperature, setWaterInletTemperature, setWaterOutletTemperature, setWaterPressure and setCoolingWaterSalinity. Do not force the water property package on the process gas. Require return temperature above supply temperature. Utility demand alone does not prove a specified UA can reach the process target.
  5. For CoolingWaterSystem, use setCoolingWaterPressure in bara separately from setSystemPressureDrop in bar. Set setCoolingWaterSalinity; supply and return temperature setters use Celsius. Remove tower fan demand for a once-through seawater system by setting its power fraction to zero.
  6. Establish equilibrium and call initProperties() before transport getters or geometry-based rating. Liquid water uses IAPWS viscosity/conductivity; seawater uses the G10-15 conductivity increment and a published salinity viscosity multiplier. Do not replace these with unexplained constants.

Validate and report

  • Close total mass and enthalpy on each side; check utility demand against the independent reference enthalpy rise and actual inlet volume. Duty is W in HeatExchanger/WaterCooler; CoolingWaterSystem requirements are kW.
  • Check terminal approaches, positive flow and capacity ordering. Retain the existing secant heat-capacity/NTU approximation; a terminal approach check does not qualify internal pinch behavior or boiling.
  • Inspect neqsim.thermo.util.steam.SeawaterProperties validity before using results. The implemented bulk cooling envelope is 273.15–353 K, 1–120 bara, 0–120 g/kg. Above 313 K or 42 g/kg, saline pressure derivatives are extrapolations. Report this and the high-pressure extension of the seawater viscosity multiplier. Reject actual states outside the implemented envelope.
  • Test nearby seasonal T/S/flow, repeated runs, changed salinity and fouling cases. Preserve rejected or nonconverged points. The seawater capacity probe may be bounded below the hot-feed temperature; this does not permit an actual utility outlet outside its model range.
  • Change salinity on the live stream fluid after a run, then rerun dependent equipment. Stream.run() clones fluid state; the original fluid passed to its constructor need not remain the live object.
  • Cite IAPWS AN5-13(2016), R13-08, R12-08, R15-11, G10-15 and the viscosity source. Record version, units, salinity basis, model, assumptions and balance residuals. Use CoolingWaterReferenceTest, ReferenceCoolingWaterTest and ReferenceWaterHeatExchangerTest as executable evidence, not a claim of field qualification or material/corrosion suitability.
  • Escalate freeze/boiling margin, fouling allowances, discharge limits, chlorination, corrosion, material selection and mechanical design to their engineering workflows using actual design evidence. Do not infer those results from thermophysical properties alone.

Download now (ZIP)

Does it work?

Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.

No reviews yet

People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.

  • It worked
  • Partly
  • It didn't
What did you use it for? e.g. Reviewing pull requests in a Rails app

Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.

Your trail

Files you open will collect here, so you can find them again.

Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.

Now do this for your own.

Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.