neqsim-water-dewpoint-dehydration-screening
Skill4 starsChanged 5 months agoApache-2.0View on GitHub
Educational gas water-content and dehydration screening using the public GPSA Bukacek saturated-water-content correlation. USE WHEN: a task needs a public, screening-level estimate of saturated water content in natural gas, a check against a sales-gas water spec, or a decision on whether a stated stream composition is already DEHYDRATED or merely cooled and knocked out (the saturation test), before detailed dehydration design or before asserting any hydrate/ice finding.
In this repository90 other files it gives its agents.
- neqsim-document-intelligence-extractionSkill
- neqsim-co2-emissions-screeningSkill
- neqsim-energy-emissions-screeningSkill
- neqsim-weather-dataSkill
- neqsim-anp-open-dataSkill
- neqsim-artificial-lift-screeningSkill
- neqsim-asset-value-npv-screeningSkill
- neqsim-capex-opex-screeningSkill
- neqsim-design-basis-screeningSkill
- neqsim-economy-basis-screeningSkill
- neqsim-ncs-infrastructure-networkSkill
- neqsim-ncs-ownership-equitySkill
- neqsim-ncs-value-chain-optimizationSkill
- neqsim-norwegian-continental-shelf-dataSkill
- neqsim-psc-bid-economics-screeningSkill
- neqsim-reservoir-depletion-screeningSkill
- neqsim-reservoir-facility-value-chainSkill
- neqsim-reservoir-model-builderSkill
- neqsim-resource-classification-screeningSkill
- neqsim-hydrate-margin-checkSkill
- neqsim-hydrate-screeningSkill
- neqsim-multiphase-flow-slug-screeningSkill
- neqsim-olga-multiphase-simulatorSkill
- neqsim-produced-water-scale-screeningSkill
- neqsim-surf-cooldown-screeningSkill
- neqsim-two-phase-flow-regime-screeningSkill
- neqsim-wax-margin-checkSkill
- neqsim-acoustic-induced-vibration-screeningSkill
- neqsim-adsorbent-capillary-condensation-screeningSkill
- neqsim-ageing-life-extension-screeningSkill
- neqsim-cfd-couplingSkill
- neqsim-compressor-antisurge-recycleSkill
- neqsim-compressor-operating-window-checkSkill
- neqsim-compressor-power-screeningSkill
- neqsim-continuous-improvement-toolkitSkill
- neqsim-control-authority-screeningSkill
- neqsim-control-valve-cv-screeningSkill
- neqsim-dry-gas-seal-screeningSkill
- neqsim-dynamic-instrument-controller-setupSkill
- neqsim-dynamic-process-preparationSkill
- neqsim-fem-couplingSkill
- neqsim-fired-heater-duty-screeningSkill
- neqsim-flow-induced-vibration-screeningSkill
- neqsim-gas-scrubber-sizing-screeningSkill
- neqsim-gas-turbine-performance-screeningSkill
- neqsim-heat-exchanger-fouling-assessmentSkill
- neqsim-line-velocity-checkSkill
- neqsim-noise-screeningSkill
- neqsim-pipe-wall-thickness-screeningSkill
- neqsim-piping-flexibility-screeningSkill
- neqsim-pressure-drop-screeningSkill
- neqsim-pump-hydraulics-screeningSkill
- neqsim-reciprocating-compressor-screeningSkill
- neqsim-reliability-data-screeningSkill
- neqsim-sand-erosion-screeningSkill
- neqsim-separator-modellingSkill
- neqsim-teg-dehydration-modelingSkill
- neqsim-uncertainty-quantificationSkill
- neqsim-utility-balance-screeningSkill
- neqsim-benchmark-reference-dataSkill
- The first 60 shown.
The file
We split this skill into the rules it gives an agent
7 rules. About 0 are common, 7 are distinctive, and 0 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈7
Distinctive · estimate
This author's own choices. Worth a look.
0
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 16
Use this skill for public, educational gas water-content screening.
- Distinctive: line 20
When a user asks whether a gas stream needs dehydration to meet a water spec.
- Distinctive: line 21
When an agent needs a quick saturated-water-content estimate to scope a dehydration study.
- Distinctive: line 22
When examples must run without confidential dehydration designs, glycol data, or company gas specs.
- Distinctive: line 154
No proprietary dehydration designs, glycol data, or company gas specs are included.
- Distinctive: line 155
No acid-gas, salinity, or hydrate-suppression corrections are performed.
- Distinctive: line 156
No glycol contactor or regeneration performance is modeled.
≈ “Common” is an estimate: at least 1 in 5 of the 350,495 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Water Dewpoint Dehydration Screening
Use this skill for public, educational gas water-content screening. It estimates the saturated water content of natural gas using the open GPSA Bukacek correlation and compares it to a sales-gas water specification so an agent can flag whether dehydration is likely required before detailed design.
When to Use
- When a user asks whether a gas stream needs dehydration to meet a water spec.
- When an agent needs a quick saturated-water-content estimate to scope a dehydration study.
- When examples must run without confidential dehydration designs, glycol data, or company gas specs.
- Before asserting any hydrate, ice, or free-water finding — run the saturation test below to establish whether free water is actually available. A hydrate finding built on an unverified water number is the single easiest way to produce a confident wrong answer.
Is the stream already dehydrated? — the saturation test
A stated water content in a datasheet or stream table tells you nothing on its own; you have to compare it against saturation at the same pressure and temperature.
ratio = stated_water_content / saturated_water_content(P, T)
ratio ~ 1.0 -> stream is AT SATURATION: wet gas, free water available.
Water was removed (if at all) by COOLING + KNOCK-OUT, not dehydration.
ratio << 1 -> stream is DEHYDRATED (glycol contactor or molecular sieve upstream).
Typical TEG: 30-50 ppm(mol); typical sales-gas spec: ~100 ppm(mol).
ratio > 1.0 -> the stated composition carries entrained/free water, or the stated
P/T is not the condition the composition belongs to. Resolve before use.Dewatering is not dehydration
This is the trap the test exists to catch. A suction scrubber, knock-out drum, or cooler + separator removes free water and leaves the gas exactly at saturation at the separator outlet condition. It lowers the absolute water content but gives zero dryness margin — the stream re-condenses water on any subsequent cooling or expansion. Only a glycol contactor or a molecular sieve produces an actual water dew-point depression.
Seeing a scrubber on the P&ID and concluding "the gas is dry" is wrong. Seeing a contactor with a regeneration package is the evidence that matters.
Where to get the authoritative water number
Prefer the PFD heat & material balance over an equipment datasheet: the H&M stream table shows the whole removal path stream by stream (inlet -> cooled -> separator liquid -> separator gas), so the mechanism is visible, not inferred. A separator liquid stream at tens of mol-% water is direct proof of knock-out.
Two cautions when reading these:
- A datasheet water content that lands exactly on saturation is a design assumption marker, not a measurement — the process engineer set "water = saturation at inlet". Treat it as the conservative wet basis it is, and say so.
- The PFD case and the datasheet case are often different duties (different year, feed or rate), so their pressures, temperatures and water contents legitimately differ. Carry both; do not silently blend them.
Computing saturation rigorously
Bukacek (below) is fine for screening. For a decisive answer, or below 0 °C, or with significant CO2/H2S, use NeqSim CPA: add the dry components plus an excess of water so a free water phase is guaranteed, flash at the stated P and T, and read the water mole fraction back out of the gas phase.
from neqsim import jneqsim
SystemSrkCPAstatoil = jneqsim.thermo.system.SystemSrkCPAstatoil
ThermodynamicOperations = jneqsim.thermodynamicoperations.ThermodynamicOperations
def saturated_water_mole_fraction(dry_components, pressure_bara, temperature_c):
"""Water mole fraction in the gas when a free water phase is present."""
s = SystemSrkCPAstatoil(273.15 + temperature_c, pressure_bara)
total = sum(dry_components.values())
for name, x in dry_components.items():
s.addComponent(name, x / total)
s.addComponent("water", 0.05) # excess -> guarantees a free water phase
s.setMixingRule(10) # CPA
s.setMultiPhaseCheck(True)
ThermodynamicOperations(s).TPflash()
s.initProperties()
return float(s.getPhase("gas").getComponent("water").getx())Cross-check with waterDewPointTemperatureMultiphaseFlash(): if the computed water dew point of the stated composition equals the stated stream temperature, the stream is saturated.
Inputs
pressure: gas pressure in bar absolute.temperature: gas temperature in kelvin.water_spec: sales-gas water-content specification in lb/MMscf, default 7.0 (common pipeline spec).
Outputs
saturated_water_content_lb_mmscf: saturated water content from the Bukacek correlation.water_spec_lb_mmscf: the supplied water specification.spec_ratio: ratio of saturated water content to the spec.dehydration_required: whether the saturated content exceeds the spec.dehydration_warning:ok,watch, ordehydration-required.assumptions: public assumptions used by the placeholder model.
Engineering Method
The Python class WaterDewpointModel uses the open GPSA Bukacek correlation only:
- the saturated water content uses
W = A / P + B, whereAandBare public temperature-dependent terms andPis in psia. - the spec ratio compares the saturated content to the supplied water spec.
- the warning is a simple rule-based label aligned with sales-gas dehydration intent.
This is educational and screening-only logic. The Bukacek correlation is for sweet natural gas in equilibrium with liquid water and is most accurate above 32 F. It does not include acid-gas corrections, salinity, hydrate suppression, or glycol contactor performance. It is not a replacement for validated water-content and dehydration design (for example GPSA and rigorous thermodynamics) and a qualified process review.
Python Usage Pattern
from water_dewpoint_dehydration_screening import WaterDewpointModel
model = WaterDewpointModel()
result = model.evaluate(
pressure=70.0,
temperature=305.15,
)
print(result.dehydration_warning)
print(result.saturated_water_content_lb_mmscf)
print(result.dehydration_required)Related NeqSim Functionality
For validated water-content and dehydration calculations, redirect to existing NeqSim functionality:
neqsim.thermo.system.SystemSrkCPAstatoil(CPA equation of state) — rigorous water content and water dew point for natural gas.neqsim.process.design.template.DehydrationTemplate— TEG dehydration process template.neqsim.process.equipment.absorberglycol contactor models — detailed dehydration performance.
This skill is a public Bukacek triage layer that decides when to invoke validated NeqSim water-content and dehydration models.
Validation Checklist
- Pressure and temperature are positive and in the stated units.
- Example inputs are public and synthetic.
- Tests cover an in-spec case, a dehydration-required case, and invalid input.
- Results are described as educational screening indicators.
- Real design is redirected to validated methods, GPSA, NeqSim CPA, and qualified review.
Common Mistakes
| Symptom | Cause | Fix |
| Water content too low | Acid-gas content ignored | Add CO2 and H2S corrections with a validated method |
| Spec check wrong | Volume basis mismatch (MMscf vs MMsm3) | Keep the water spec on the same basis as the correlation |
| Out-of-range result | Temperature below the correlation range | Use a validated method below freezing or near hydrate conditions |
| "There is a scrubber, so the gas is dry" | Confusing dewatering with dehydration | Run the saturation test; a scrubber leaves the gas AT saturation |
| Hydrate finding collapses under review | Water basis never verified | Run the saturation test before asserting any hydrate/ice consequence |
| Two documents disagree on water content | Different operating cases (year, feed, rate) | Carry both cases; do not blend or silently pick one |
dewPointTemperatureFlash() raises IsNaNException: molarVolumeAnalytical - compressibility factor is NaN | Requested dew point at or above the cricondenbar, where no dew point exists | Guard the call, or get the cricondentherm/cricondenbar from calcPTphaseEnvelope instead |
Limitations
- No proprietary dehydration designs, glycol data, or company gas specs are included.
- No acid-gas, salinity, or hydrate-suppression corrections are performed.
- No glycol contactor or regeneration performance is modeled.
References
- NeqSim repository: https://github.com/equinor/neqsim
- NeqSim Skills Guide: https://github.com/equinor/neqsim/blob/master/docs/integration/skills_guide.md
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.