neqsim-gas-turbine-performance-screening
Skill4 starsChanged 5 months agoApache-2.0View on GitHub
Educational gas-turbine performance screening using open ISO 3977 / GL1029 style derate factors. USE WHEN: a task needs a public, screening-level estimate of site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature for a gas-turbine driver before detailed package selection.
In this repository90 other files it gives its agents.
- neqsim-document-intelligence-extractionSkill
- neqsim-co2-emissions-screeningSkill
- neqsim-energy-emissions-screeningSkill
- neqsim-weather-dataSkill
- neqsim-anp-open-dataSkill
- neqsim-artificial-lift-screeningSkill
- neqsim-asset-value-npv-screeningSkill
- neqsim-capex-opex-screeningSkill
- neqsim-design-basis-screeningSkill
- neqsim-economy-basis-screeningSkill
- neqsim-ncs-infrastructure-networkSkill
- neqsim-ncs-ownership-equitySkill
- neqsim-ncs-value-chain-optimizationSkill
- neqsim-norwegian-continental-shelf-dataSkill
- neqsim-psc-bid-economics-screeningSkill
- neqsim-reservoir-depletion-screeningSkill
- neqsim-reservoir-facility-value-chainSkill
- neqsim-reservoir-model-builderSkill
- neqsim-resource-classification-screeningSkill
- neqsim-hydrate-margin-checkSkill
- neqsim-hydrate-screeningSkill
- neqsim-multiphase-flow-slug-screeningSkill
- neqsim-olga-multiphase-simulatorSkill
- neqsim-produced-water-scale-screeningSkill
- neqsim-surf-cooldown-screeningSkill
- neqsim-two-phase-flow-regime-screeningSkill
- neqsim-wax-margin-checkSkill
- neqsim-acoustic-induced-vibration-screeningSkill
- neqsim-adsorbent-capillary-condensation-screeningSkill
- neqsim-ageing-life-extension-screeningSkill
- neqsim-cfd-couplingSkill
- neqsim-compressor-antisurge-recycleSkill
- neqsim-compressor-operating-window-checkSkill
- neqsim-compressor-power-screeningSkill
- neqsim-continuous-improvement-toolkitSkill
- neqsim-control-authority-screeningSkill
- neqsim-control-valve-cv-screeningSkill
- neqsim-dry-gas-seal-screeningSkill
- neqsim-dynamic-instrument-controller-setupSkill
- neqsim-dynamic-process-preparationSkill
- neqsim-fem-couplingSkill
- neqsim-fired-heater-duty-screeningSkill
- neqsim-flow-induced-vibration-screeningSkill
- neqsim-gas-scrubber-sizing-screeningSkill
- neqsim-heat-exchanger-fouling-assessmentSkill
- neqsim-line-velocity-checkSkill
- neqsim-noise-screeningSkill
- neqsim-pipe-wall-thickness-screeningSkill
- neqsim-piping-flexibility-screeningSkill
- neqsim-pressure-drop-screeningSkill
- neqsim-pump-hydraulics-screeningSkill
- neqsim-reciprocating-compressor-screeningSkill
- neqsim-reliability-data-screeningSkill
- neqsim-sand-erosion-screeningSkill
- neqsim-separator-modellingSkill
- neqsim-teg-dehydration-modelingSkill
- neqsim-uncertainty-quantificationSkill
- neqsim-utility-balance-screeningSkill
- neqsim-water-dewpoint-dehydration-screeningSkill
- neqsim-benchmark-reference-dataSkill
- The first 60 shown.
The file
We split this skill into the rules it gives an agent
4 rules. About 0 are common, 4 are distinctive, and 0 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈4
Distinctive · estimate
This author's own choices. Worth a look.
0
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 20
When a user asks how much power a gas-turbine driver makes at site conditions versus its ISO rating.
- Distinctive: line 21
When an agent needs a quick site heat rate, fuel heat input, or exhaust mass flow estimate for waste-heat or HRSG scoping.
- Distinctive: line 22
When examples must run without confidential vendor performance maps or company package specs.
- Distinctive: line 112
No proprietary vendor performance maps, fuel composition effects, or company specs are included.
≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Gas Turbine Performance Screening
Use this skill for public, educational gas-turbine performance screening. It corrects an ISO base rating for ambient temperature, site elevation, and inlet/exhaust pressure losses to estimate site-rated shaft power, site heat rate, thermal efficiency, fuel heat input, exhaust mass flow, and exhaust temperature so an agent can scope a driver-selection study before detailed package review.
When to Use
- When a user asks how much power a gas-turbine driver makes at site conditions versus its ISO rating.
- When an agent needs a quick site heat rate, fuel heat input, or exhaust mass flow estimate for waste-heat or HRSG scoping.
- When examples must run without confidential vendor performance maps or company package specs.
Inputs
iso_base_power_kw: ISO base-load shaft power rating in kW.iso_heat_rate_kj_kwh: ISO base-load heat rate in kJ/kWh.ambient_temperature_k: site ambient temperature in kelvin, default 288.15 (ISO reference).site_elevation_m: site elevation above sea level in m, default 0.relative_humidity: site relative humidity fraction, default 0.6 (small effect).inlet_pressure_loss_mbar: inlet system pressure loss in mbar, default 10.exhaust_pressure_loss_mbar: exhaust system pressure loss in mbar, default 10.required_shaft_power_kw: optional driven-equipment shaft power in kW for the margin check.
Outputs
site_power_kw: derated site shaft power.ambient_derate_factor: ambient-temperature power factor.altitude_derate_factor: site-elevation power factor.pressure_loss_derate_factor: combined inlet/exhaust pressure-loss power factor.total_derate_factor: product of all derate factors.site_heat_rate_kj_kwh: site heat rate after efficiency degradation.thermal_efficiency: shaft thermal efficiency from the site heat rate.fuel_heat_input_kw: fuel lower-heating-value heat input.exhaust_mass_flow_kg_s: screening exhaust mass flow.exhaust_temperature_k: screening exhaust temperature.power_margin_ratio: site power divided by required shaft power, ornull.power_warning:ok,watch,insufficient-power, orno-rating.assumptions: public assumptions used by the placeholder model.
Engineering Method
The Python class GasTurbinePerformanceModel uses open performance-derate relations only:
- ambient derate uses
f_amb = 1 - 0.007 (T_amb - 288.15), clamped at zero. - altitude derate uses
f_alt = 1 - 1.1e-4 * elevation, from reduced barometric pressure. - pressure-loss derate uses
f_inlet = 1 - 0.002 * dP_inletandf_exhaust = 1 - 0.001 * dP_exhaust. - site power uses
P_site = P_iso * f_amb * f_alt * f_inlet * f_exhaust * f_humidity. - site heat rate uses
HR_site = HR_iso (1 + 0.5 (1 - f_total))so efficiency falls with derate. - fuel heat input uses
Q_fuel = P_site * HR_site / 3600. - exhaust mass flow uses a fixed specific-flow factor
m_exh = P_site * 0.003.
This is educational and screening-only logic. It assumes linear derates, a fixed specific exhaust flow, and a typical exhaust temperature. It is not a replacement for validated gas-turbine performance models or qualified package review.
Python Usage Pattern
from gas_turbine_performance_screening import GasTurbinePerformanceModel
model = GasTurbinePerformanceModel()
result = model.evaluate(
iso_base_power_kw=30000.0,
iso_heat_rate_kj_kwh=9500.0,
ambient_temperature_k=303.15,
site_elevation_m=50.0,
required_shaft_power_kw=26000.0,
)
print(result.site_power_kw)
print(result.site_heat_rate_kj_kwh)
print(result.power_warning)Related NeqSim Functionality
For validated power-generation calculations, redirect to NeqSim classes:
neqsim.process.equipment.powergeneration.GasTurbine— gas-turbine driver model with fuel and exhaust calculations.neqsim.process.equipment.powergeneration.HRSG— heat-recovery steam generator using turbine exhaust.neqsim.process.equipment.powergeneration.CombinedCycleSystem— combined-cycle integration of turbine and steam systems.
This skill is a public triage layer that decides when to invoke a validated gas-turbine model.
Validation Checklist
- ISO base power and heat rate are positive.
- Ambient temperature is positive and elevation is non-negative.
- Tests cover ambient derate, the power margin, the fuel/efficiency estimate, and invalid input.
- Results are described as educational screening indicators.
- Real driver selection is redirected to validated NeqSim power-generation classes and qualified review.
Common Mistakes
| Symptom | Cause | Fix |
| Site power above ISO rating | Ambient below 288.15 K | Screening caps uprate; treat sub-ISO gains conservatively |
| Power margin missing | No required shaft power supplied | Provide required_shaft_power_kw for the margin check |
| Exhaust flow looks flat | Fixed specific-flow factor used | Use a validated gas-turbine model for HRSG sizing |
Limitations
- No proprietary vendor performance maps, fuel composition effects, or company specs are included.
- Derates are linear screening factors; part-load, water injection, and DLE effects are not modelled.
- Exhaust mass flow and temperature use fixed screening assumptions, not a heat-and-mass balance.
Related Skills
neqsim-weather-data- live or historical site ambient temperature (and elevation from location resolution) to feedambient_temperature_k/site_elevation_minstead of an assumed value.
References
- ISO 3977, Gas turbines — Procurement.
- ISO 2314, Gas turbines — Acceptance tests.
- NeqSim repository: https://github.com/equinor/neqsim
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.

