neqsim-energy-emissions-screening
Skill4 starsChanged 5 months agoApache-2.0View on GitHub
Educational field-life energy and CO2-equivalent emissions roll-up that turns a year-by-year energy use into annual and total CO2e, a carbon intensity (kg CO2e/boe), and an optional CO2-tax cost. USE WHEN: a task needs a public, screening-level field-life emissions and carbon-intensity picture before detailed NeqSim combustion modelling or certified emission reporting.
In this repository90 other files it gives its agents.
- neqsim-document-intelligence-extractionSkill
- neqsim-co2-emissions-screeningSkill
- neqsim-weather-dataSkill
- neqsim-anp-open-dataSkill
- neqsim-artificial-lift-screeningSkill
- neqsim-asset-value-npv-screeningSkill
- neqsim-capex-opex-screeningSkill
- neqsim-design-basis-screeningSkill
- neqsim-economy-basis-screeningSkill
- neqsim-ncs-infrastructure-networkSkill
- neqsim-ncs-ownership-equitySkill
- neqsim-ncs-value-chain-optimizationSkill
- neqsim-norwegian-continental-shelf-dataSkill
- neqsim-psc-bid-economics-screeningSkill
- neqsim-reservoir-depletion-screeningSkill
- neqsim-reservoir-facility-value-chainSkill
- neqsim-reservoir-model-builderSkill
- neqsim-resource-classification-screeningSkill
- neqsim-hydrate-margin-checkSkill
- neqsim-hydrate-screeningSkill
- neqsim-multiphase-flow-slug-screeningSkill
- neqsim-olga-multiphase-simulatorSkill
- neqsim-produced-water-scale-screeningSkill
- neqsim-surf-cooldown-screeningSkill
- neqsim-two-phase-flow-regime-screeningSkill
- neqsim-wax-margin-checkSkill
- neqsim-acoustic-induced-vibration-screeningSkill
- neqsim-adsorbent-capillary-condensation-screeningSkill
- neqsim-ageing-life-extension-screeningSkill
- neqsim-cfd-couplingSkill
- neqsim-compressor-antisurge-recycleSkill
- neqsim-compressor-operating-window-checkSkill
- neqsim-compressor-power-screeningSkill
- neqsim-continuous-improvement-toolkitSkill
- neqsim-control-authority-screeningSkill
- neqsim-control-valve-cv-screeningSkill
- neqsim-dry-gas-seal-screeningSkill
- neqsim-dynamic-instrument-controller-setupSkill
- neqsim-dynamic-process-preparationSkill
- neqsim-fem-couplingSkill
- neqsim-fired-heater-duty-screeningSkill
- neqsim-flow-induced-vibration-screeningSkill
- neqsim-gas-scrubber-sizing-screeningSkill
- neqsim-gas-turbine-performance-screeningSkill
- neqsim-heat-exchanger-fouling-assessmentSkill
- neqsim-line-velocity-checkSkill
- neqsim-noise-screeningSkill
- neqsim-pipe-wall-thickness-screeningSkill
- neqsim-piping-flexibility-screeningSkill
- neqsim-pressure-drop-screeningSkill
- neqsim-pump-hydraulics-screeningSkill
- neqsim-reciprocating-compressor-screeningSkill
- neqsim-reliability-data-screeningSkill
- neqsim-sand-erosion-screeningSkill
- neqsim-separator-modellingSkill
- neqsim-teg-dehydration-modelingSkill
- neqsim-uncertainty-quantificationSkill
- neqsim-utility-balance-screeningSkill
- neqsim-water-dewpoint-dehydration-screeningSkill
- neqsim-benchmark-reference-dataSkill
- The first 60 shown.
The file
We split this skill into the rules it gives an agent
5 rules. About 0 are common, 5 are distinctive, and 0 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈5
Distinctive · estimate
This author's own choices. Worth a look.
0
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 16
Use this skill for a quick, public roll-up of field-life energy use into emissions.
- Distinctive: line 26
When a user wants total and per-year CO2e and a carbon intensity for a concept.
- Distinctive: line 27
When an agent needs an emissions/cost feed for an asset-value chain.
- Distinctive: line 28
When examples must run without certified emission factors or confidential data.
- Distinctive: line 116
No confidential data or proprietary methods are included.
≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Energy & Emissions Screening
Use this skill for a quick, public roll-up of field-life energy use into
emissions. Given a year-by-year energy use (MWh), a public emission factor, and an
optional production profile, it returns annual and total CO2-equivalent
emissions, a carbon intensity in kg CO2e per barrel of oil equivalent, and an
optional CO2-tax cost. It complements the instantaneous combustion skill
neqsim-co2-emissions-screening by aggregating over the field life and adding
carbon intensity and cost.
When to Use
- When a user wants total and per-year CO2e and a carbon intensity for a concept.
- When an agent needs an emissions/cost feed for an asset-value chain.
- When examples must run without certified emission factors or confidential data.
Inputs
annual_energy_use_mwh: sequence of annual energy use in MWh (one per year).emission_factor_kg_co2e_per_mwh: public emission factor (default 450).annual_production_boe: a flat value or a per-year sequence in boe (default 0).co2_tax_usd_per_tonne: optional CO2 tax (default 0).
Outputs
annual_co2e_tonnes: per-year CO2-equivalent emissions in tonnes.total_co2e_tonnes: total field-life CO2e in tonnes.total_energy_use_mwh: total field-life energy use.carbon_intensity_kg_per_boe: total CO2e (kg) divided by total production (boe), orNone.annual_emission_cost_musd/total_emission_cost_musd: CO2-tax cost in million USD.intensity_warning:ok,watch,high, orno-production.neqsim_available: whether the optional NeqSim package is importable.assumptions: public assumptions and required follow-up.
Engineering Method
Annual CO2e is energy_use_MWh * emission_factor_kg/MWh / 1000 (kg to tonnes).
Total CO2e and total energy are the year sums. Carbon intensity is
total_CO2e_kg / total_production_boe (undefined when production is zero). The
CO2-tax cost is annual_CO2e_tonnes * tax_USD/tonne / 1e6 (million USD). The
verdict compares carbon intensity to a configurable threshold (default 17 kg
CO2e/boe, a public global-average order of magnitude).
This skill uses a single public emission factor and models no combustion efficiency, methane slip, flaring, venting, allowances, or capture credit. It is a placeholder that must be replaced by validated NeqSim combustion modelling and certified emission factors for any quantitative or reporting use.
Python Usage Pattern
from energy_emissions_screening import EnergyEmissionsModel
model = EnergyEmissionsModel()
result = model.evaluate(
annual_energy_use_mwh=[120000.0, 180000.0, 175000.0, 150000.0, 120000.0],
emission_factor_kg_co2e_per_mwh=450.0,
annual_production_boe=[3.0e6, 7.0e6, 6.5e6, 5.0e6, 3.5e6],
co2_tax_usd_per_tonne=85.0,
)
print(result.total_co2e_tonnes)
print(result.carbon_intensity_kg_per_boe)
print(result.total_emission_cost_musd)
print(result.intensity_warning)Validated NeqSim Path
This screening is a placeholder. For real emission accounting use:
- NeqSim
neqsim.standards.gasquality.Standard_ISO6976for calorific value. - NeqSim
neqsim.process.equipment.powergeneration.GasTurbinefor fuel-gas consumption and turbine duty. - NeqSim
neqsim.process.equipment.reactor.GibbsReactorfor equilibrium combustion products, and theneqsim-co2-emissions-screeningskill for a per-stream combustion-CO2 rate.
Escalation
Escalate any high verdict, any reporting use, and any carbon-tax exposure to
validated NeqSim combustion modelling, certified emission factors, and qualified
environmental reporting.
Validation Checklist
- Inputs are validated and within stated ranges.
- Examples use public data only.
- Screening assumptions are stated explicitly.
- Limitations are respected.
- Quantitative use is escalated to validated NeqSim models.
Common Mistakes
| Symptom | Cause | Fix |
| Unrealistic result | Inputs outside the screening range | Keep inputs within the stated bounds |
| Misused for design | Screening output taken as final | Escalate to validated NeqSim models |
Limitations
- Educational screening only; not a validated design method.
- No confidential data or proprietary methods are included.
- Escalate any quantitative or design use to validated NeqSim workflows.
References
- NeqSim repository: https://github.com/equinor/neqsim
- NeqSim Skills Guide: https://github.com/equinor/neqsim/blob/master/docs/integration/skills_guide.md
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.

