neqsim-acoustic-induced-vibration-screening
Skill4 starsChanged 5 months agoApache-2.0View on GitHub
Educational acoustic-induced-vibration (AIV) screening using the public Energy Institute likelihood-of-failure form for gas pressure-reducing devices. USE WHEN: a task needs a public, screening-level estimate of sound power level, pipe diameter-to-thickness ratio, allowable sound power level, and an AIV likelihood-of-failure index for a control valve, relief valve, or restriction orifice before detailed vibration assessment.
In this repository90 other files it gives its agents.
- neqsim-document-intelligence-extractionSkill
- neqsim-co2-emissions-screeningSkill
- neqsim-energy-emissions-screeningSkill
- neqsim-weather-dataSkill
- neqsim-anp-open-dataSkill
- neqsim-artificial-lift-screeningSkill
- neqsim-asset-value-npv-screeningSkill
- neqsim-capex-opex-screeningSkill
- neqsim-design-basis-screeningSkill
- neqsim-economy-basis-screeningSkill
- neqsim-ncs-infrastructure-networkSkill
- neqsim-ncs-ownership-equitySkill
- neqsim-ncs-value-chain-optimizationSkill
- neqsim-norwegian-continental-shelf-dataSkill
- neqsim-psc-bid-economics-screeningSkill
- neqsim-reservoir-depletion-screeningSkill
- neqsim-reservoir-facility-value-chainSkill
- neqsim-reservoir-model-builderSkill
- neqsim-resource-classification-screeningSkill
- neqsim-hydrate-margin-checkSkill
- neqsim-hydrate-screeningSkill
- neqsim-multiphase-flow-slug-screeningSkill
- neqsim-olga-multiphase-simulatorSkill
- neqsim-produced-water-scale-screeningSkill
- neqsim-surf-cooldown-screeningSkill
- neqsim-two-phase-flow-regime-screeningSkill
- neqsim-wax-margin-checkSkill
- neqsim-adsorbent-capillary-condensation-screeningSkill
- neqsim-ageing-life-extension-screeningSkill
- neqsim-cfd-couplingSkill
- neqsim-compressor-antisurge-recycleSkill
- neqsim-compressor-operating-window-checkSkill
- neqsim-compressor-power-screeningSkill
- neqsim-continuous-improvement-toolkitSkill
- neqsim-control-authority-screeningSkill
- neqsim-control-valve-cv-screeningSkill
- neqsim-dry-gas-seal-screeningSkill
- neqsim-dynamic-instrument-controller-setupSkill
- neqsim-dynamic-process-preparationSkill
- neqsim-fem-couplingSkill
- neqsim-fired-heater-duty-screeningSkill
- neqsim-flow-induced-vibration-screeningSkill
- neqsim-gas-scrubber-sizing-screeningSkill
- neqsim-gas-turbine-performance-screeningSkill
- neqsim-heat-exchanger-fouling-assessmentSkill
- neqsim-line-velocity-checkSkill
- neqsim-noise-screeningSkill
- neqsim-pipe-wall-thickness-screeningSkill
- neqsim-piping-flexibility-screeningSkill
- neqsim-pressure-drop-screeningSkill
- neqsim-pump-hydraulics-screeningSkill
- neqsim-reciprocating-compressor-screeningSkill
- neqsim-reliability-data-screeningSkill
- neqsim-sand-erosion-screeningSkill
- neqsim-separator-modellingSkill
- neqsim-teg-dehydration-modelingSkill
- neqsim-uncertainty-quantificationSkill
- neqsim-utility-balance-screeningSkill
- neqsim-water-dewpoint-dehydration-screeningSkill
- neqsim-benchmark-reference-dataSkill
- The first 60 shown.
The file
We split this skill into the rules it gives an agent
4 rules. About 0 are common, 4 are distinctive, and 0 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈4
Distinctive · estimate
This author's own choices. Worth a look.
0
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 20
When a user asks whether a control valve, relief valve, or restriction orifice creates an AIV risk.
- Distinctive: line 21
When an agent needs a quick sound-power-level and LOF estimate downstream of a high pressure drop.
- Distinctive: line 22
When examples must run without confidential valve data, vendor noise curves, or company specs.
- Distinctive: line 105
No proprietary valve data, vendor noise curves, or company specs are included.
≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Acoustic-Induced Vibration Screening
Use this skill for public, educational acoustic-induced-vibration (AIV) screening of gas pressure-reducing devices. It estimates the generated sound power level, the pipe diameter-to-thickness ratio, an allowable sound power level, and a likelihood-of-failure (LOF) index so an agent can scope an AIV study before a detailed piping-vibration assessment. It complements the flow-induced-vibration-screening skill, which covers gas flow-induced vibration through a kinetic-energy index.
When to Use
- When a user asks whether a control valve, relief valve, or restriction orifice creates an AIV risk.
- When an agent needs a quick sound-power-level and LOF estimate downstream of a high pressure drop.
- When examples must run without confidential valve data, vendor noise curves, or company specs.
Inputs
mass_flow_kg_s: gas mass flow through the device in kg/s.upstream_pressure_bar: upstream pressureP1in bar absolute.downstream_pressure_bar: downstream pressureP2in bar absolute.pipe_outside_diameter_mm: downstream pipe outside diameter in mm.wall_thickness_mm: downstream pipe wall thickness in mm.molecular_weight: gas molecular weight, default 19.temperature_k: gas temperature in kelvin, default 313.15.downstream_pipe_length_m: downstream pipe length in m, default 10.sound_power_level_db: optional measured/known sound power level; if omitted it is computed.
Outputs
pressure_drop_ratio:(P1 - P2) / P1.sound_power_level_db: supplied or computed sound power level in dB.diameter_thickness_ratio: pipeD / t.allowable_sound_power_level_db: allowable sound power level from theD / tcorrelation.likelihood_of_failure: dimensionless AIV LOF index.downstream_pipe_length_m: echoed downstream pipe length.risk_warning:low-risk,medium-risk, orhigh-risk.assumptions: public assumptions used by the placeholder model.
Engineering Method
The Python class AcousticInducedVibrationModel uses the open Energy Institute / Carucci-Mueller AIV screening form only:
- sound power level uses
PWL = 10 log10[(dP/P1)^3.6 * mdot^2 * (T/MW)^1.2] + constant. - diameter-to-thickness ratio uses
D / t. - allowable sound power level uses
PWL_allow = reference - slope * (D / t), so higherD / tlowers the limit. - likelihood of failure uses
LOF = 1 + (PWL - PWL_allow) / spread, clamped at zero, so higherPWLand higherD / tboth raise the LOF.
This is educational and screening-only logic. The correlation constants are documented screening approximations, not certified AIV limits. It assumes a single gas pressure-reducing device, ignores branch-connection geometry, weld type, and downstream fitting layout, and is not a replacement for a validated AIV assessment or qualified piping-vibration review.
Python Usage Pattern
from acoustic_induced_vibration_screening import AcousticInducedVibrationModel
model = AcousticInducedVibrationModel()
result = model.evaluate(
mass_flow_kg_s=12.0,
upstream_pressure_bar=90.0,
downstream_pressure_bar=20.0,
pipe_outside_diameter_mm=323.9,
wall_thickness_mm=9.5,
)
print(result.sound_power_level_db)
print(result.likelihood_of_failure)
print(result.risk_warning)Related NeqSim Functionality
For validated vibration screening, redirect to NeqSim classes:
neqsim.process.safety.vibration.AcousticInducedVibrationLOF— proposed AIV likelihood-of-failure model (PWL, D/t, allowable-PWL correlation); candidate NeqSim gap.neqsim.process.safety.vibration.FlowInducedVibrationLOF— proposed flow-induced-vibration model; candidate NeqSim gap.- The
flow-induced-vibration-screeningcommunity skill — gas flow-induced vibration through a kinetic-energy index.
This skill is a public triage layer that decides when to invoke a validated AIV assessment.
Validation Checklist
- Upstream and downstream pressures are positive and
P1 > P2. - Pipe outside diameter exceeds twice the wall thickness.
- Tests cover sound-power-level computation, a supplied sound-power-level path, a high-risk case, and invalid input.
- Results are described as educational screening indicators.
- Real assessment is redirected to validated NeqSim vibration classes and qualified review.
Common Mistakes
| Symptom | Cause | Fix |
| LOF unexpectedly high | Large D / t thin-wall pipe | Use a thicker wall or smaller diameter |
| LOF always zero | Very low sound power level | Confirm the pressure-drop and flow inputs |
| Computed PWL ignored | sound_power_level_db supplied | Omit it to let the correlation compute PWL |
Limitations
- No proprietary valve data, vendor noise curves, or company specs are included.
- Branch-connection geometry, weld type, and downstream fitting layout are not modelled.
- The correlation constants are documented screening approximations only.
References
- Energy Institute, Guidelines for the Avoidance of Vibration Induced Fatigue Failure in Process Pipework, 2nd Edition.
- Carucci, V. A., and Mueller, R. T., Acoustically Induced Piping Vibration in High Capacity Pressure Reducing Systems, ASME 82-WA/PVP-8.
- NeqSim repository: https://github.com/equinor/neqsim
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.

