Educational SURF flowline/riser cooldown and no-touch-time screening placeholder with public assumptions. USE WHEN: a task needs a quick, public estimate of how long an insulated subsea flowline stays above its hydrate formation temperature after shutdown, and should be directed to validated NeqSim methods for real cooldown and hydrate calculations.

The file

We split this skill into the rules it gives an agent

9 rules. About 0 are common, 7 are distinctive, and 2 are very specific to this project.

  • ≈0

    Common · estimate

    Many files like this have a rule of this kind.

  • ≈7

    Distinctive · estimate

    This author's own choices. Worth a look.

  • 2

    Very specific

    Tied to their project's names, files or tools. Probably skip.

  • Common
  • Distinctive
  • Very specific
  1. Distinctive:

    Use this skill for a quick, public estimate of the no-touch time of an insulated subsea flowline or riser after a shutdown: how long the …

    line 16
  2. Distinctive:

    When a user asks roughly how long a subsea line can be left after shutdown before reaching the hydrate region.

    line 25
  3. Distinctive:

    When a validated NeqSim hydrate equilibrium temperature and a lumped thermal time constant (or the data to estimate one) are already …

    line 27
  4. Distinctive:

    When an agent should explain that validated NeqSim methods are required for real cooldown, no-touch-time, and inhibitor design.

    line 29
  5. Very specific:

    If the hydrate temperature is at or below the seabed temperature (or no value is supplied), the line never enters the hydrate region and …

    line 66
  6. Very specific:

    If the optional neqsim Python package is available, the result records that fact so an agent can recommend moving to validated NeqSim …

    line 104
  7. Distinctive:

    No hydrate phase equilibrium, salinity, methanol, MEG, or kinetics here.

    line 131
  8. Distinctive:

    No proprietary insulation data or company cooldown specifications.

    line 132
  9. Distinctive:

    Not suitable for design no-touch time, inhibitor dosage, or operating-limit decisions.

    line 133

≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.

Keep what fits and drop the rest. Your version, ready for your agents.
Files
SKILL.md

SURF Cooldown Screening

Use this skill for a quick, public estimate of the no-touch time of an insulated subsea flowline or riser after a shutdown: how long the trapped fluid stays above its hydrate formation temperature (plus a safety margin) before remedial action (depressurization or inhibitor injection) is required. It is intentionally simple and should guide users toward validated NeqSim cooldown and hydrate workflows for real work.

When to Use

  • When a user asks roughly how long a subsea line can be left after shutdown before reaching the hydrate region.
  • When a validated NeqSim hydrate equilibrium temperature and a lumped thermal time constant (or the data to estimate one) are already available.
  • When an agent should explain that validated NeqSim methods are required for real cooldown, no-touch-time, and inhibitor design.

Inputs

  • initial_temperature: fluid temperature at shutdown in C.
  • seabed_temperature: ambient seabed (sink) temperature in C.
  • hydrate_equilibrium_temperature: hydrate formation temperature in C from a validated NeqSim calculation.
  • time_constant_hours: lumped exponential cooldown time constant in hours.
  • hydrate_margin: configurable margin above the hydrate temperature in C (constructor, default 3.0).
  • required_no_touch_time: optional operational target in hours (constructor).

A helper, time_constant_from_lumped_mass, estimates time_constant_hours from fluid density, specific heat, internal diameter, and an overall U-value using the public lumped relation tau = rho * cp * D / (4 * U).

Outputs

  • no_touch_time_hours: time to cool to the hydrate target temperature.
  • target_temperature_c: hydrate equilibrium temperature plus the margin.
  • verdict: ok, marginal, critical, or no_hydrate_risk.
  • neqsim_available: whether the optional NeqSim package is importable.
  • assumptions: public assumptions and required follow-up.

Engineering Method

The placeholder uses a single-node (lumped) exponential cooldown:

T(t) = T_seabed + (T_initial - T_seabed) * exp(-t / tau)

Solving for the time to reach the hydrate target temperature T_target = T_hydrate + margin:

t_no_touch = -tau * ln((T_target - T_seabed) / (T_initial - T_seabed))

If the hydrate temperature is at or below the seabed temperature (or no value is supplied), the line never enters the hydrate region and the verdict is no_hydrate_risk. Verdict bands: with a required no-touch time, ok at or above the requirement, marginal at or above 75% of it, otherwise critical. Without a requirement, ok at 12 h or more, marginal at 6 h or more, otherwise critical.

This is not a distributed thermal-hydraulic model. The hydrate equilibrium temperature and the thermal time constant must come from validated NeqSim calculations with a defined fluid composition, water content, geometry, and insulation basis.

Python Usage Pattern

from surf_cooldown_screening import SurfCooldownModel

model = SurfCooldownModel(hydrate_margin=3.0, required_no_touch_time=8.0)

tau = SurfCooldownModel.time_constant_from_lumped_mass(
    fluid_density=180.0,        # kg/m3 (dense gas)
    specific_heat=2600.0,       # J/kg.K
    internal_diameter=0.254,    # m
    overall_u_value=2.5,        # W/m2.K
)

result = model.evaluate(
    initial_temperature=65.0,
    seabed_temperature=4.0,
    hydrate_equilibrium_temperature=20.0,
    time_constant_hours=tau,
)

print(result.no_touch_time_hours)
print(result.verdict)
print(result.assumptions)

If the optional neqsim Python package is available, the result records that fact so an agent can recommend moving to validated NeqSim cooldown workflows. If not, the example still runs with fallback placeholder logic.

Validation Checklist

  • Initial, seabed, and hydrate temperatures are finite.
  • The hydrate equilibrium temperature came from a validated NeqSim calculation.
  • The time constant came from a validated lumped or distributed model.
  • No-hydrate-risk and in-region cases are tested.
  • The hydrate margin and verdict bands are documented as configurable public guidelines only.
  • Results are not used as a design no-touch time or an operating limit.
  • Real cooldown work is redirected to validated NeqSim methods and qualified flow assurance review.

Common Mistakes

SymptomCauseFix
No-touch time looks generous but hydrates form earlyTime constant underestimated (insulation too optimistic)Use a validated U-value and lumped/distributed cooldown model
Verdict always no_hydrate_riskHydrate temperature below seabed or omittedSupply a validated NeqSim hydrate equilibrium temperature
No-touch time negative or undefinedInitial temperature already at or below the hydrate targetConfirm the operating point and recompute with NeqSim

Limitations

  • Single-node lumped model only; no axial profile, no transient depressurization.
  • No hydrate phase equilibrium, salinity, methanol, MEG, or kinetics here.
  • No proprietary insulation data or company cooldown specifications.
  • Not suitable for design no-touch time, inhibitor dosage, or operating-limit decisions.

Related NeqSim Functionality

This educational screening corresponds to validated, rigorous functionality in the NeqSim Java library that a qualified engineer should use for design-grade work:

  • neqsim.pvtsimulation.flowassurance.SurfCooldownAnalyzer — couples a live fluid to a lumped cooldown engine, auto-extracts density, specific heat, and the hydrate equilibrium temperature, and reports the no-touch time and verdict.
  • neqsim.pvtsimulation.flowassurance.PipelineCooldownCalculator — lumped layer/U-value cooldown engine with time-to-temperature and time-constant outputs.
  • neqsim.thermodynamicoperations.ThermodynamicOperations#hydrateFormationTemperature() — rigorous hydrate equilibrium temperature.

In Python the same classes are reachable through the neqsim package (for example from neqsim import jneqsim).

Related Skills

  • neqsim-weather-data - live or historical sea-surface temperature (get_marine) as an ambient/seabed-temperature indicator when no direct seabed measurement is available.

References

  • NeqSim repository: https://github.com/equinor/neqsim
  • DNV-RP-F109, On-bottom stability / thermal design background (public guidance).
  • API RP 17A, Subsea production systems (public scope background).

Download now (ZIP)

Does it work?

Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.

No reviews yet

People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.

  • It worked
  • Partly
  • It didn't
What did you use it for? e.g. Reviewing pull requests in a Rails app

Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.

Your trail

Files you open will collect here, so you can find them again.

Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.

Now do this for your own.

Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.