two-phase-flow
Skill7 starsChanged 6 months agoApache-2.0View on GitHub
Estimate frictional pressure drop for gas-liquid two-phase pipe flow using Lockhart-Martinelli (horizontal), Beggs-Brill (inclined, all angles), or Mueller-Steinhagen-Heck (smooth quality interpolation). Use when sizing flare lines, two-phase risers, knock-out drum inlets, or boiler-tube pressure drop. Don't use for single-phase pipe flow (use pipe-flow-pressure-drop), or for choked / sonic flow (different physics).
In this repository31 other files it gives its agents.
- absorption-stripping-designSkill
- bayesian-hierarchical-process-modelsSkill
- caustic-merox-extractionSkill
- censored-regressionSkill
- compositional-data-analysisSkill
- control-valve-sizing-isa75Skill
- convective-heat-transfer-correlationsSkill
- design-of-experimentsSkill
- dimensionless-numbersSkill
- distillation-shortcut-designSkill
- distributed-lag-modelsSkill
- engg-skills-commonSkill
- engineering-skill-creatorSkill
- engineering-statisticsSkill
- equation-of-state-selectionSkill
- heat-exchanger-sizingSkill
- literature-search-engineeringSkill
- material-energy-balancesSkill
- pipe-flow-pressure-dropSkill
- process-causal-inference-dagsSkill
- process-units-conversionSkill
- reactor-sizing-and-kineticsSkill
- relief-valve-sizing-api520Skill
- separator-vessel-sizingSkill
- sour-gas-amine-treatingSkill
- statistical-process-controlSkill
- steam-tables-iapwsSkill
- thermo-process-propertiesSkill
- time-series-process-data-analysisSkill
- uvSkill
- vle-flash-calculationsSkill
The file
We split this skill into the rules it gives an agent
4 rules. About 0 are common, 2 are distinctive, and 2 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈2
Distinctive · estimate
This author's own choices. Worth a look.
2
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Distinctive: line 70
Run two correlations and compare.
- Very specific: line 95
If fluids is not installed, escalate to the user.
- Very specific: line 103
Run the listed script with representative inputs and an --output file when a deterministic calculation is available.
- Distinctive: line 105
Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.
≈ “Common” is an estimate: at least 1 in 5 of the 372,429 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Two-Phase Pressure Drop
Overview
Three established gas-liquid two-phase pressure-drop correlations from the
fluids.two_phase module. Each correlation has its strengths:
- Lockhart-Martinelli: classical horizontal, widely cited, ±30% typical.
- Beggs-Brill: handles inclination (essential for risers, hilly pipelines).
- Mueller-Steinhagen-Heck: smooth interpolation between all-liquid and all-vapor frictional gradients; recommended starting point for refrigerant evaporator design.
Prerequisites
uvavailable.- On first use, the script writes
LICENSE_NOTIFICATION.txtlisting thefluidslibrary terms.
When to Use
- Two-phase frictional pressure drop is needed in a pipe (flare, reboiler return, riser, knock-out drum inlet, slug catcher manifold).
- Comparing two correlations to bracket the design pressure drop.
Don't use for
- Single-phase pipe flow — use
pipe-flow-pressure-drop. - Choked / sonic flow at a relief valve outlet — use
relief-valve-sizing-api520. - Two-phase across a control valve — consult vendor methods; the control-valve sizing skill only covers liquid/gas ISA sizing, not two-phase trim rating.
Utility Scripts
uv run scripts/two_phase.py lm --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/lm.jsonuv run scripts/two_phase.py beggs-brill --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --sigma 0.02 --P 1000000 --D 0.1 --L 50 --angle 30 --output /tmp/bb.jsonuv run scripts/two_phase.py msh --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/msh.json
Procedure
- Establish phase mass flow rates and quality
x = m_g / (m_g + m_l). - Get phase densities and viscosities at operating conditions (use
vle-flash-calculationsif needed). - Pick a correlation:
- Horizontal, dilute liquid: Lockhart-Martinelli.
- Inclined, any angle, oil/gas pipeline: Beggs-Brill.
- Refrigerant / process evaporator, smooth quality range: Mueller- Steinhagen-Heck.
- Run two correlations and compare; use the higher dP for the design margin unless one is clearly outside its validity range.
Pitfalls
- Using a single-phase friction factor on a two-phase stream.
- Treating the slip ratio as 1 (homogeneous) for high-quality steam — fine for refrigerant boiling, not for low-pressure flashing systems.
- Ignoring vapor density variation along the pipe; for long lines the acceleration term can dominate at the outlet.
- Picking Lockhart-Martinelli for a vertical riser; it does not include gravity head.
- Picking Beggs-Brill horizontal mode at 0° without verifying the correlation switches to the appropriate flow regime.
- Forgetting that quality changes when heat is added or pressure drops (flashing or condensing). The correlations assume a constant quality over the pipe length L; for large dP / large dT, segment the pipe.
- Reporting only one correlation's number; a 2x spread between correlations is normal for two-phase flow.
- Using these correlations for entrained-droplet flow at high vapor velocity with a demister downstream; entrainment loading matters and is not in the correlation.
Fallback Strategies
- If
fluidsis not installed, escalate to the user; there is no clean pure-Python fallback for Beggs-Brill that captures all flow regimes. - For very high quality (x → 1), the Lockhart-Martinelli parameter X approaches 0 and the correlation degrades; switch to a homogeneous-flow approximation or to Mueller-Steinhagen-Heck.
Verification
- Run the listed script with representative inputs and an
--outputfile when a deterministic calculation is available. - Confirm the JSON result contains
ok: true, expected units, and no unhandled warnings. - Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.
References
references/correlation_choice.md— when each correlation is most suitable.- Beggs & Brill, Two-Phase Flow in Pipes (Univ Tulsa Press, 1991).
- Lockhart & Martinelli, Chem Eng Prog 45, 1949.
- Mueller-Steinhagen & Heck, Chem Eng Proc 20, 1986.
fluidsdocumentation: https://fluids.readthedocs.io/fluids.two_phase.html
Anti-Patterns
- Picking one correlation and not documenting why.
- Designing a flare line without checking back-pressure on multiple PRV cases.
- Treating two-phase dP as if it were 1.2x single-phase dP — that shortcut fails dramatically in slug flow.
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.