Estimate frictional pressure drop for gas-liquid two-phase pipe flow using Lockhart-Martinelli (horizontal), Beggs-Brill (inclined, all angles), or Mueller-Steinhagen-Heck (smooth quality interpolation). Use when sizing flare lines, two-phase risers, knock-out drum inlets, or boiler-tube pressure drop. Don't use for single-phase pipe flow (use pipe-flow-pressure-drop), or for choked / sonic flow (different physics).

The file

We split this skill into the rules it gives an agent

4 rules. About 0 are common, 2 are distinctive, and 2 are very specific to this project.

  • ≈0

    Common · estimate

    Many files like this have a rule of this kind.

  • ≈2

    Distinctive · estimate

    This author's own choices. Worth a look.

  • 2

    Very specific

    Tied to their project's names, files or tools. Probably skip.

  • Common
  • Distinctive
  • Very specific
  1. Distinctive:

    Run two correlations and compare.

    line 70
  2. Very specific:

    If fluids is not installed, escalate to the user.

    line 95
  3. Very specific:

    Run the listed script with representative inputs and an --output file when a deterministic calculation is available.

    line 103
  4. Distinctive:

    Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.

    line 105

≈ “Common” is an estimate: at least 1 in 5 of the 372,429 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.

Keep what fits and drop the rest. Your version, ready for your agents.
Files
SKILL.md

Two-Phase Pressure Drop

Overview

Three established gas-liquid two-phase pressure-drop correlations from the fluids.two_phase module. Each correlation has its strengths:

  • Lockhart-Martinelli: classical horizontal, widely cited, ±30% typical.
  • Beggs-Brill: handles inclination (essential for risers, hilly pipelines).
  • Mueller-Steinhagen-Heck: smooth interpolation between all-liquid and all-vapor frictional gradients; recommended starting point for refrigerant evaporator design.

Prerequisites

  1. uv available.
  2. On first use, the script writes LICENSE_NOTIFICATION.txt listing the fluids library terms.

When to Use

  • Two-phase frictional pressure drop is needed in a pipe (flare, reboiler return, riser, knock-out drum inlet, slug catcher manifold).
  • Comparing two correlations to bracket the design pressure drop.

Don't use for

  • Single-phase pipe flow — use pipe-flow-pressure-drop.
  • Choked / sonic flow at a relief valve outlet — use relief-valve-sizing-api520.
  • Two-phase across a control valve — consult vendor methods; the control-valve sizing skill only covers liquid/gas ISA sizing, not two-phase trim rating.

Utility Scripts

  • uv run scripts/two_phase.py lm --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/lm.json
  • uv run scripts/two_phase.py beggs-brill --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --sigma 0.02 --P 1000000 --D 0.1 --L 50 --angle 30 --output /tmp/bb.json
  • uv run scripts/two_phase.py msh --m 5.0 --quality 0.3 --rho-l 600 --rho-g 30 --mu-l 0.0002 --mu-g 1.0e-5 --D 0.1 --L 50 --output /tmp/msh.json

Procedure

  1. Establish phase mass flow rates and quality x = m_g / (m_g + m_l).
  2. Get phase densities and viscosities at operating conditions (use vle-flash-calculations if needed).
  3. Pick a correlation:
    • Horizontal, dilute liquid: Lockhart-Martinelli.
    • Inclined, any angle, oil/gas pipeline: Beggs-Brill.
    • Refrigerant / process evaporator, smooth quality range: Mueller- Steinhagen-Heck.
  4. Run two correlations and compare; use the higher dP for the design margin unless one is clearly outside its validity range.

Pitfalls

  • Using a single-phase friction factor on a two-phase stream.
  • Treating the slip ratio as 1 (homogeneous) for high-quality steam — fine for refrigerant boiling, not for low-pressure flashing systems.
  • Ignoring vapor density variation along the pipe; for long lines the acceleration term can dominate at the outlet.
  • Picking Lockhart-Martinelli for a vertical riser; it does not include gravity head.
  • Picking Beggs-Brill horizontal mode at 0° without verifying the correlation switches to the appropriate flow regime.
  • Forgetting that quality changes when heat is added or pressure drops (flashing or condensing). The correlations assume a constant quality over the pipe length L; for large dP / large dT, segment the pipe.
  • Reporting only one correlation's number; a 2x spread between correlations is normal for two-phase flow.
  • Using these correlations for entrained-droplet flow at high vapor velocity with a demister downstream; entrainment loading matters and is not in the correlation.

Fallback Strategies

  • If fluids is not installed, escalate to the user; there is no clean pure-Python fallback for Beggs-Brill that captures all flow regimes.
  • For very high quality (x → 1), the Lockhart-Martinelli parameter X approaches 0 and the correlation degrades; switch to a homogeneous-flow approximation or to Mueller-Steinhagen-Heck.

Verification

  • Run the listed script with representative inputs and an --output file when a deterministic calculation is available.
  • Confirm the JSON result contains ok: true, expected units, and no unhandled warnings.
  • Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.

References

  • references/correlation_choice.md — when each correlation is most suitable.
  • Beggs & Brill, Two-Phase Flow in Pipes (Univ Tulsa Press, 1991).
  • Lockhart & Martinelli, Chem Eng Prog 45, 1949.
  • Mueller-Steinhagen & Heck, Chem Eng Proc 20, 1986.
  • fluids documentation: https://fluids.readthedocs.io/fluids.two_phase.html

Anti-Patterns

  • Picking one correlation and not documenting why.
  • Designing a flare line without checking back-pressure on multiple PRV cases.
  • Treating two-phase dP as if it were 1.2x single-phase dP — that shortcut fails dramatically in slug flow.

Download now (ZIP)

Does it work?

Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.

No reviews yet

People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.

  • It worked
  • Partly
  • It didn't
What did you use it for? e.g. Reviewing pull requests in a Rails app

Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.

Your trail

Files you open will collect here, so you can find them again.

Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.

Now do this for your own.

Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.