absorption-stripping-design
Skill7 starsChanged 6 months agoApache-2.0View on GitHub
Apply the Kremser absorption/stripping factor method for dilute systems and packed/tray column HETP / efficiency screening. Use when sizing an absorber or stripper, estimating per-stage performance for a dilute solute, or sanity-checking a vendor sizing. Don't use for reactive absorption with chemical equilibrium (use sour-gas-amine-treating), highly concentrated systems (Kremser assumes dilute), or rate-based packed-column design with detailed mass-transfer correlations.
In this repository31 other files it gives its agents.
- bayesian-hierarchical-process-modelsSkill
- caustic-merox-extractionSkill
- censored-regressionSkill
- compositional-data-analysisSkill
- control-valve-sizing-isa75Skill
- convective-heat-transfer-correlationsSkill
- design-of-experimentsSkill
- dimensionless-numbersSkill
- distillation-shortcut-designSkill
- distributed-lag-modelsSkill
- engg-skills-commonSkill
- engineering-skill-creatorSkill
- engineering-statisticsSkill
- equation-of-state-selectionSkill
- heat-exchanger-sizingSkill
- literature-search-engineeringSkill
- material-energy-balancesSkill
- pipe-flow-pressure-dropSkill
- process-causal-inference-dagsSkill
- process-units-conversionSkill
- reactor-sizing-and-kineticsSkill
- relief-valve-sizing-api520Skill
- separator-vessel-sizingSkill
- sour-gas-amine-treatingSkill
- statistical-process-controlSkill
- steam-tables-iapwsSkill
- thermo-process-propertiesSkill
- time-series-process-data-analysisSkill
- two-phase-flowSkill
- uvSkill
- vle-flash-calculationsSkill
The file
We split this skill into the rules it gives an agent
2 rules. About 0 are common, 1 is distinctive, and 1 is very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈1
Distinctive · estimate
This author's own choices. Worth a look.
1
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Very specific: line 98
Run the listed script with representative inputs and an --output file when a deterministic calculation is available.
- Distinctive: line 100
Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.
≈ “Common” is an estimate: at least 1 in 5 of the 372,429 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Absorption and Stripping Shortcut Design
Overview
Implements the Kremser equation and helpers for stage counting in dilute
absorber/stripper systems. The Kremser formulation is exact for systems with
constant absorption factor A = L / (K V) and a linear equilibrium
relationship y* = K x.
For concentrated systems, reactive absorbers, or rate-based design, use a rigorous simulator or rate-based correlation; this skill is screening only.
Prerequisites
uvavailable.- On first use the script writes
LICENSE_NOTIFICATION.txt.
When to Use
- Sizing a dilute absorber (lean oil, glycol dehydrator screening, dilute acid-gas scrubber).
- Estimating the stripping factor and stage count for a desorber.
- Cross-checking vendor sizing for a tray or packed column.
Don't use for
- Reactive absorption with chemical equilibrium (DEA/MDEA + acid gas):
use
sour-gas-amine-treatingfor screening or a rate-based simulator. - Concentrated solute (mole fraction > 5-10%): Kremser breaks down.
- Detailed packing-specific design: use vendor correlations or a rate-based simulator.
Utility Scripts
uv run scripts/kremser.py --N 8 --A 1.4 --K 0.5 --y-in 0.02 --x-in 0.0 --output /tmp/kremser.jsonuv run scripts/kremser.py --N 8 --A 0.8 --K 0.5 --y-in 0.02 --x-in 0.0 --output /tmp/stripper.json
Procedure
- Decide on solute, lean-solvent K-value at column conditions (often
evaluated at a representative
T). - Pick a target removal fraction (e.g. 95% of solute absorbed).
- Compute the required absorption factor
A = L / (K V); aim forA = 1.2 - 1.5(industry rule of thumb for non-reactive dilute systems). - Solve Kremser for
Nstages. - Convert equilibrium stages to actual stages with a Murphree efficiency (~0.5 - 0.8 for trays; for packed beds, divide column height by HETP).
- Sanity-check operating line vs equilibrium line: lines must not cross.
Pitfalls
- Using Kremser for a reactive absorber. The acid-gas + amine system needs a different framework.
- Picking
A = 1.0(or just slightly above) and reporting it as feasible; it implies infinite stages at the limit. - Using a single
Kfor the whole column when K varies strongly with T or composition. Average it with care. - Confusing absorption factor
A = L/(KV)with stripping factorS = K V/L. - Reporting equilibrium stages as actual trays without applying efficiency.
- Forgetting to verify that the operating line and equilibrium line do not
cross within the column (a sign that the requested removal is infeasible at
the chosen
A). - Picking
L/Gfrom the gas mass balance only — heat balance and rich solvent loading change the effectiveL. - Using Kremser for solute mole fractions > 5-10%; non-linear equilibrium
invalidates the constant-
Aassumption.
Fallback Strategies
- For reactive absorption, switch to
sour-gas-amine-treating(screening) or a rate-based simulator (ProMax, ProTreat, Aspen rate-based). - For high-concentration systems, do a manual stage-by-stage operating / equilibrium analysis on a y-x diagram with varying K.
Verification
- Run the listed script with representative inputs and an
--outputfile when a deterministic calculation is available. - Confirm the JSON result contains
ok: true, expected units, and no unhandled warnings. - Check result magnitudes against the stated assumptions, references, and a hand calculation or known operating range before reporting them.
References
references/kremser_derivation.md— derivation and assumptions.- Treybal, Mass-Transfer Operations.
- Sinnott, Coulson & Richardson, Volume 6.
Anti-Patterns
- Reporting "5 actual trays" without specifying Murphree efficiency.
- Picking
Afrom the recommended range without justifying it from capex/opex trade-off. - Mixing up "absorption factor" with "absorption efficiency".
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.