tia-harness / codex
AGENTS.md12 starsChanged 27 days agoMITView on GitHub
Note: The block between the tia-harness markers below is GENERATED from mcp/content/ (run cd mcp && npm run sync) — do not hand-edit its body. This header (outside the markers) is specific to the Codex port and is edited normally. The harness pieces arrive through the tia-harness Codex plugin and one copy step: - Skills come with the plugin, listed as tia-harness:<name> (each with its YAML frontmatter + auxiliary files like RULES.md/RECIPES.md/CPU-TABLE.md/BASELINE.md). - Subagents are copied to <codex home>/agents/<name>.toml (tia-engineer,…
Where files are headingNew AGENTS.md files have more rules about keeping secrets out of the code, and fewer about code style.
Of the AGENTS.md files we read, the 31,700 first seen in the last six months, against the older ones: the kind of rule that gained most share, and the kind that lost most. About files like this in general, not this one, and an estimate, since a kind is a pattern in the words.
In this repository10 other files it gives its agents.
- .claude-plugin/CLAUDE.mdCLAUDE.md
- cpu-selectSkill
- spec-planSkill
- spec-validateSkill
- tia-backupSkill
- tia-handoffSkill
- tia-initSkill
- tia-reviewSkill
- tia-scaffoldSkill
- tia-verifySkill
The file
We split this AGENTS.md into the rules it gives an agent
10 rules. About 0 are common, 1 is distinctive, and 9 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈1
Distinctive · estimate
This author's own choices. Worth a look.
9
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Very specific: line 71
Prerequisites: run the serve (http://localhost:5000.
- Very specific: line 84
Before the first build on a project: read tia_guide {"topic":"pipeline"} and tia_guide {"topic":"gotchas"}.
- Very specific: line 114
Fresh 1214C communication settings: PUT/GET, OPC UA license and HR interface need a human source configuration.
- Very specific: line 172
One serial worker: never concurrent tia_* calls.
- Very specific: line 197
A V17 program does not upload into V21 (2026-10-31): use the TIA version the program was made with.
- Very specific: line 252
Use the PlcSoftware name from tia_plcs, not the device name.
- Very specific: line 268
Confirmation dialog: When the client supports elicitation, the crossing calls (tia_download with approved:true.
- Very specific: line 284
Before edits, use target, kind, filter:"ObjectsWithReferences".
- Very specific: line 298
Read first (tia_subnet_get, tia_device_network, tia_io_systems), then run each write's dryRun (answered by the serve, needs an open …
- Distinctive: line 344
Not copied here: Codex reads at most 32 KiB of AGENTS.md and cuts the rest without a word.
≈ “Common” is an estimate: at least 1 in 5 of the 40,246 AGENTS.md files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
Note: The block between the
tia-harnessmarkers below is GENERATED frommcp/content/(runcd mcp && npm run sync) — do not hand-edit its body. This header (outside the markers) is specific to the Codex port and is edited normally.
Working with the TIA Portal Automation Harness (Codex)
The harness pieces arrive through the tia-harness Codex plugin and one copy step:
- Skills come with the plugin, listed as
tia-harness:<name>(each with its YAML frontmatter + auxiliary files likeRULES.md/RECIPES.md/CPU-TABLE.md/BASELINE.md). - Subagents are copied to
<codex home>/agents/<name>.toml(tia-engineer, hardware-architect, verifier, safety-reviewer). - The
tiaMCP is registered by the plugin. See ../docs/INSTALL.md for the exact install/uninstall steps and the remote-serveoverride. - Connect through PLCWare (Windows app) plus
npx plcware-setup. Setup installs this official Codex plugin through its native CLI and records its changes for exact uninstall; it does not copy an independent MCP/skills harness. See README.md for advanced manual installation.
<!-- tia-harness:start -->TIA Openness MCP — operating brief
You are driving Siemens TIA Portal V21 through the tia_* tools (an MCP over the TIA
Openness HTTP serve). This brief is ALWAYS in effect. For depth, call the tia_guide
tool (topics: gates-guards, gui-gates, gotchas, pipeline, recipes,
spec-format) — read the relevant topic BEFORE authoring blocks, changing hardware,
or preparing a deploy. You are an assistant up to the gate, never an autonomous
commissioner.
Vocabulary (used across all tool descriptions)
- Class R — read-only; safe anytime.
- Class M-off — offline mutation (edits the project; never touches the physical PLC).
- Class GATE — touches the physical world or a human-only decision; needs a human.
- G1..G7 — the GATES: G1 trust dialog, G2 S7-connection precondition (tool-enforced: both CPUs must compile clean), G3 download / CPU-STOP, G4 go-online (incl. station upload), G5 safety / F-logic (NEVER autonomous), G6 credentials — master secret, UMAC, upload / block / certificate passwords, password policy (from a human — never invented), G7 network scan. All except G2 are human-only — never crossed autonomously.
- Gd* — tool-enforced GUARDS (preconditions the tools check), e.g. Gd5
OrderNumber:<MLFB>/V<fw>format (slash before V, never:V), Gd8 only ERRORs block a compile (warnings don't), Gd9 clean compile before deploy, Gd11 dryRun-then-approve.
Non-negotiable rules
- Serial only. The serve owns ONE TIA Portal on ONE serial worker. Never fire
concurrent
tia_*calls; one hung Openness call can stall the whole serve. - Never cross a GATE autonomously. A
requires_human_actionresponse is a HANDOFF, not an error: relay itsyouMustDo/nextStepsto the human verbatim, wait for their explicit yes, then resume exactly as instructed. Never self-approve a download; never invent a secret (G6); never author, modify or deploy safety/F logic (G5). - Long operations are jobs. Long tools (connect, compile, download, upload,
project create/save/archive, exports, CAx…) may answer
status:"running"with ajobId— the operation is STILL running on serve. Calltia_job_status {jobId}until it returns the final result; never repeat the original call. Onkind:"busy", polltia_job_statusonly for a running job whosejobIdis known (e.g.details.jobId).tia_pingprobes/health: never busy, no job ID — use it for reachability only. Without a known running job ID, wait/recheck withtia_status; forconnect_incomplete, follow the host-inspection handoff (tia_guide {"topic":"gui-gates"}), never retry connect. Offline tools (tia_guide,tia_spec_validate,tia_spec_plan,tia_job_status) never answer busy. - Compile before deploy.
tia_compileaggregates hardware + software and is the offline verifier:errors:0is the Gd9 precondition for download (G3) and for S7 connections. - Follow the build pipeline order (details:
tia_guide {"topic":"pipeline"}): validate the spec (tia_spec_validate) → plan (tia_spec_plan) → scaffold (tia_spec_applyor the M-off tools) → verify (tia_compile) → human-gated deploy (tia_downloadwith dryRun → human approval →approved:true+ the sameplanHash). - Fresh CPUs may need GUI setup (PUT/GET, OPC UA license/interface); a prepared station can
inherit these via
tia_device_from_mastercopy. Readtia_guide {"topic":"gui-gates"}. Missing settings are human handoffs, not retryable failures. - Prerequisites: run the serve (
http://localhost:5000;tia_ping). First connect per process may need G1; running/timeout alone are not G1 evidence. - Confirmation dialogs. Where the client supports it, a gated call first asks the human in the client's dialog
(elicitation); only the human answers it, and it never replaces dryRun → approval →
planHash.declined_by_human/cancelled_by_human= refused, nothing sent: stop, no retry unless asked. - Size budget and paging. A result holding
{"omitted":true,…}had that value cut out WHOLE by the MCP's size budget: repeating the same call returns the same marker, so follow itshintinstead. Read large lists (tia_plc_blocks,tia_plc_tags,tia_device_tree) in pages: passlimit, then eachnextCursorascursoruntil it isnull. A page with a marker has NOnextCursor(it would skip the omitted data): retry the same request with a smallerlimit.cursor_stalemeans the project changed: restart from the first page (nocursor). Gate handoffs, plans and job envelopes are never cut. For XML too big for one result usetia_export_xml(it writes files on the serve host).
Session start: tia_ping → tia_status → (if needed) tia_start / tia_connect.
Before the first build on a project: read tia_guide {"topic":"pipeline"} and
tia_guide {"topic":"gotchas"}.
Tool names are written bare (tia_status) here and in the skills. Claude Code shows them qualified:
mcp__plugin_tia-harness_tia__tia_status (plugin; what a subagent tools: list needs) or
mcp__tia__tia_status (standalone). Other clients may display them differently; the tia_* suffix
is the tool.
Gates vs guards
GATES vs GUARDS
- GATES (human-only — never auto-bypass): trust dialog (G1), download / CPU-STOP
(G3), go-online (G4, which includes a station upload (
tia_upload): it goes online to read the CPU), network scan / accessible-devices (G7), master-secret/UMAC (G6, which includes a CPU read-access password for an upload, a block know-how password (tia_block_protect), a certificate file's password (tia_certificate_import) and the password-policy values (tia_password_policy_set)), safety / F-logic (G5) — never autonomous. - GUARDS (tool-enforced preconditions): compile-clean before deploy, consistency,
dry-run→approve, idempotency by name (advisory: re-runs do not converge),
OrderNumber:<MLFB>/V<fw>format, serial-only. - Back up a physical CPU with the
tia-backupskill (dedicated empty project; the upload token is bound to the project shown in the handoff). - Picking the G3 download path (no gate, no scan):
tia_pg_interfaceslists the connection modes/PG-PC interfaces TIA already sees for the CPU (plus the OS status of each adapter) — use it to fillconnectionMode/pcInterfaceName/targetInterfaceNamefortia_downloadinstead of reaching fortia_accessible_devices(a real network scan, GATE G7). - Fresh 1214C communication settings: PUT/GET, OPC UA license and HR interface need a
human source configuration;
tia_device_from_mastercopycan inherit it into a new station. Server activation is scriptable:tia_obj_set_attributes {handle, attributes:{OpcUaServer:true}}. Details and certificate recovery:tia_guide {"topic":"gui-gates"}. Never script the GUI.
Deploy-time approval gates (download / online / network-scan / secret / safety = G3/G4/G7/G6/G5)
are a different class — see the tia-handoff skill. Those are "a human approves an action",
not "a human clicks a GUI setting". Both are human interaction points; surface them as
requires_human_action with concrete guidance, never as a tool failure.
GUI gates — expected human interaction points
Human interaction points (GUI gates) — EXPECTED, not an error
Expected handoffs include trust, fresh-CPU setup and firmware-change recovery. On the validated 1214C V4.4, no direct setter for PUT/GET, license selection or HR mapping was verified; a prepared station master copy inherits all three. Do not blindly retry a missing setting: give the human the exact steps.
| # | Signal you'll see | Why it's expected | Tell the human (exact GUI steps) |
| G1 trust | EngineeringSecurityException or a failed start with details.cause:"trust" → requires_human_action / trust_dialog. Neither running nor the 20-minute client timeout (STARTING_UNCONFIRMED) proves G1 or success. | First attach may prompt per serve process. | Human on the serve host: click "Yes to all" only on a visible trust dialog. While a job runs, poll tia_job_status; do not queue calls. A timeout does not cancel it: inspect the host, wait for completion before status/retry. After explicit G1 handoff, retry with resumeToken. For TRUST_DIALOG_DENIED_OR_EXPIRED, inspect closedPids/stillRunningPids/unknownPids: close only verified remaining TIA started by serve with no open project, then retry with a human ready. |
| OPC UA license | tia_compile ERROR: "The selected OPC UA license is not sufficient…" | No verified direct setter on this 1214C; a fresh project or firmware change can leave it unset | CPU → Properties → General → Runtime licenses → OPC UA → required "SIMATIC OPC UA S7-1200 Basic"; purchased → the license the owner declares for this CPU. Recompile. |
| OPC UA interface | OPC UA client connects but the DB nodes aren't there (ns=4 empty / no ServerInterfaces) | The validated S7-1200 requires a configured server interface to expose DBs | CPU → OPC UA communication → Server interfaces → Add new server interface → type Interface → drop the HR array (ModbusData.HR), not the DB or individual elements. Recompile. |
| PUT/GET | S7 client connects on port 102 but reads return access-denied | No verified direct setter on this 1214C | CPU → Properties → Protection & Security → Connection mechanisms → check "Permit access with PUT/GET communication from remote partner". Compile + human-gated download (hardware:true). |
| FW-change reset | After tia_device_change_version: OPC UA server off, the license error on compile, blocks isConsistent:false | DeviceItem.ChangeType resets GUI-gated comm settings (server activation + license); the interface & PUT/GET survive | tia_project_archive before the FW change. After: re-set OpcUaServer:true via tia_obj_set_attributes (scriptable), re-select the license (row above), recompile. |
Bounded connect: connect_incomplete / CONNECT_UNCONFIRMED (serve_host_inspection)
names the last phase, not G1 or success. No cancellation or TIA kill: don't repeat or queue work.
Human: inspect the host and answer pending Siemens dialogs. If none is pending and unresponsive,
save stdout (CLI) or %APPDATA%\TIAOpenness\startup.log (tray, overwritten on launch),
then restart the process (tray: Exit/relaunch, not API Stop/Start).
TIA may remain running: inspect it and verify project state before reconnecting.
A finished MCP job carrying this handoff isn't connection proof.
Prepared station: tia_library_mastercopy_create {device}, then tia_device_from_mastercopy {masterCopy}
clones all three settings and HR mappings. Not an existing-CPU setter or license grant.
Certificates are not copied: on the NEW "OPC UA" item, OpcUaServer:false then true regenerated one; compile afterwards.
GUI type Interface maps to SimaticInterface (Export, no Import).
The separate ServerInterface.Import did not reproduce its HR mappings.
1214C/V21 bench, 2026-10-26: HR[0..2] IDs in ns=4: HR array → 13,14,15;
individual elements → 12,23,34; whole DB → 14,15,16.
Selection/order affects IDs; probe after construction/import.
Hard-won gotchas (runtime-validated)
Hard-won gotchas
- Always compile before deploy.
tia_compileaggregates hardware + software; a clean compile (errors:0) is the precondition for download and for S7 connections.tia_downloadcompiles too and leaves the project modified (projectModifiedin plan/result): save (tia_project_save) before switching projects; Openness does not say what changed. First download over another project's or TIA version's program: planallowUpgradeTargetDevice:true, or a refusal may leave the CPU stopped (the plan cannot predict it). - One serial worker: never concurrent
tia_*calls; a hung operation may need a serve restart. - FB edits: software-scope
tia_compile; export regenerated DBs (blockChanges). Still inconsistent:tia_block_delete+tia_instancedb_create, recompile. Global DB source put re-creates it:IsOnlyStoredInLoadMemoryresets (no source support; pragma ignored); nested starts needBEGIN. UDT put/tia_types_importdid not reset DB values. Save XML/text/flags. InspectchangeImpact.dbAttributeChanges/readGaps(unknown;trackChanges:falseopts out). Restore flag=true:tia_block_set_attribute, compile; starts: saved XML/text, not attributes. N warnings then 0: hardware compile produced OPC UA guest/unsecured + missing protection-level warnings; next skipped hardware. Checkmessages[]"Hardware configuration". - Firmware rule: project FW ≤ device FW. Bump the project FW in-place with
tia_device_change_version(DeviceItem.ChangeType), which preserves the program — never set the project higher than the physical CPU. ⚠️ It RESETS GUI-gated comm settings (the OPC UA server activation + runtime-license; the server interface and PUT/GET survive): archive first (tia_project_archive) on a CPU with hand-configured OPC UA, recompile after (it marks blocks inconsistent), and re-verify. Same-versionChangeTypeis rejected. - Use a NON-optimized DB for Modbus (
MB_HOLD_REG) and S7 (absolute addressing); OPC UA works with optimized or not. - Order numbers use
/V<fw>, not:V<fw>(guard Gd5). - A station upload (
tia_upload) ADDS a new station to the open project — back up into a dedicated EMPTY project. Bench (S7-1200 1214C, 2026-09-26): 0 → 1 device in ~75 s, twice, with the CPU in RUN throughout. Protect the working project FIRST:tia_project_createcloses it and is refused (409 unsaved_changes) while it has unsaved changes, sotia_project_save+tia_project_archivefirst (neverdiscardUnsavedChangesto get past the refusal), with the archivenameWITH the.zap21extension (absent or extension-less fails). A V17 program does not upload into V21 (2026-10-31): use the TIA version the program was made with.upload_incompatible_versionis definite: check versions andstationAddedindetails; a partial station is not a backup. Approval stays single-use. - One wrong know-how password can lock a block for the session. Observed on the bench
(2026-10-12): after one rejected unprotect (
tia_block_protect {protect:false}), TIA refused the CORRECT password of that block for the rest of the session (cause not confirmed — possibly brute-force protection). Never retry with a guess — ask the human for the password (G6); if a password the human confirms is refused, stop and hand off instead of retrying. unsaved_changesandbinding_conflictare refusals, not faults: nothing was changed.tia_connect,tia_project_close,tia_disconnectandtia_project_createanswer409 unsaved_changeswhen the call would close a project with unsaved changes (the error lists each one). ASK the human; the recommended answer is to repeat the same call withsaveUnsavedChanges:true. PassdiscardUnsavedChanges:true(data loss) ONLY when the human explicitly decides to throw the work away, never to make the error go away (the client then asks the human to confirm in its own dialog;declined_by_human= nothing was sent, stop).409 binding_conflictmeans the project this session is bound to is no longer the one open in the bound TIA (closed, replaced or Save As done by hand;tia_statusshowsboundProjectPathandbindingDrift): ask the human which project is intended, thentia_connectwith the bound path (back to it) or the open one (adopt it) — do not repeat the refused call first.503 audit_unavailable: the serve could not write its audit log, so it refused the call BEFORE running (nothing reached the PLC). Have the human fix the disk or permissions, then re-plan. AnauditWarningin a response = the call ran but was not fully recorded: report it.
Prerequisites (environment)
- The
tiaserve must be running (defaulthttp://localhost:5000, e.g.TIAOpenness.exe serve 5000). The MCP is a pure HTTP client; point it at the serve host viaTIA_API_BASEif it runs elsewhere. - The Windows user must belong to the "Siemens TIA Openness" local group.
- A first connection per serve process may show a trust dialog; a human confirms it on the serve host. A slow start or timeout alone is not G1 evidence.
The build pipeline (spec → verified project)
TIA version preflight: tia_guide {"topic":"recipes"}, 'TIA version evidence and SimaticML', before authoring.
| # | Stage | Tool(s) | Class | What it does |
| 0 | Validate the spec | tia_spec_validate | R (pure) | Partial shape checks + the cross-field rules the tool implements: unique names, IP inside the subnet CIDR, Gd5 order-number format, no STL/GRAPH on S7-1200, the G5 safety rule, at most 8 SMs on an S7-1200. It does NOT run the JSON Schema or per-model module limits; the spec-validate skill covers both. Needs no serve. |
| 1 | Plan | tia_spec_plan | R (pure) | Turns a VALID spec into the ordered list of M-off operations. Nothing mutates. |
| 2 | Scaffold | tia_spec_apply (or the M-off tools manually) | M-off | Creates part of the project content in dependency order (scope below). Stops at every gate. |
| 3 | Verify | tia_compile | M-off | THE offline verifier: aggregates hardware + software. Gd8: only ERRORs block. errors:0 is the Gd9 precondition for any deploy. |
| 4 | Handoff / deploy | tia_download | GATE G3 | dryRun:true verifies compile, connection and software fingerprint → planHash → HUMAN approval → approved:true + SAME single-use planHash. Serve re-checks software (plan_stale if changed). Approval binds connection/options and covered software, NOT hardware: humans must confirm hardware has not changed since that dryRun; changed hardware needs a NEW plan and approval, never the old token. Fingerprint covers user blocks, UDTs and tag tables only; exclusions and source:"dates" fallback: tia_guide {"topic":"recipes"}, 'Reference — download plan fingerprint limits'. Never self-approve; resolve connection via tia_pg_interfaces (no scan). |
For the first download over another project's or another TIA version's program, plan with
allowUpgradeTargetDevice:true; without it, a refusal may leave the CPU stopped.
The offline plan cannot predict whether TIA will request that confirmation.
For the first download over another project's or another TIA version's program, plan with
allowUpgradeTargetDevice:true; without it, a refusal may leave the CPU stopped.
The offline plan cannot predict whether TIA will request that confirmation.
Scaffold order (UDTs BEFORE the blocks that use them): by hand, tia_guide {"topic":"recipes"}, 'Pipeline order'. tia_spec_apply automates only subnets, devices, modules, network, tag tables, tags, FB shells, control-module instance DBs and the compile; protection, constants, UDTs and all logic stay manual. The FB shells it creates are empty: add their logic with tia_source_put (SCL) or tia_import_xml (LAD/FBD).
Use the PlcSoftware name from tia_plcs, not the device name.
The approval envelope (what a gate handoff looks like)
Gated tools return status:"requires_human_action" with:
gate— which gate (e.g.download_approval,station_upload,go_online,trust_dialog);youMustDo— what the human must confirm, in plain words;plan+planHash— exactly what would be executed (the hash binds the approval to this exact plan; a changed plan needs a new approval); the download's plan also carriesfingerprint(the software content the plan was verified against — show it too);nextSteps— how to resume after the human's yes.
Relay the envelope to the human, wait for an explicit yes, resume exactly as instructed. The AI never approves, never invents a secret, never deploys F-logic.
Confirmation dialog. When the client supports elicitation, the crossing calls (tia_download with
approved:true; tia_upload, tia_online, tia_accessible_devices with confirm:true) first ask the
human in a dialog; clients without it behave as before. The dialog only checks the human's answer: the
planHash and serve's approval token stay the authority.
Passwords (G6) are never asked there. declined_by_human / cancelled_by_human = the human refused:
nothing was sent, no retry unless asked. elicitation_failed (isError) = the dialog could not be
shown or answered, nothing was sent (fails closed).
After scaffolding
- Re-run
tia_compileafter ANY authoring change. tia_project_saveregularly;tia_project_archiveBEFORE risky operations (firmware change — seetia_guide {"topic":"gotchas"}).- Auditing an existing project is class R (
tia_plc_*reads); baseline:tia_guide {"topic":"recipes"}, 'Reference — network, audit and CAx how-to'. tia_crossrefs(R, Long; polltia_job_statusforjobId):UnusedObjectsreturns CANDIDATES, not proof (OBs, external-only uses and library TYPEs can look unused). Before edits, usetarget,kind,filter:"ObjectsWithReferences"; the human interprets TIA'sreferenceType(Uses/UsedBy) andaccess. Page containers/whole PLCs withlimit+ unchangednextCursoruntil null. App 1.8+ caches whole-PLC walks until mutation/close/cursor expiry; older serves re-read pages. Read coverage on every page, not only the first: a later page can report less than an earlier one. Oncursor_stale, restart from the first page; differing counts restart the walk once from the first page. On omission retry the same request with smallerlimit, never its cursor. Claim complete/no uses ONLY after a finished walk with identical counts, no omissions andcoverage.complete:trueon EVERY page; else NOT complete (inspectcoverage.unavailableOwners).- FAT/SAT I/O list (
tia-verifystep 6):tia_io_map; recipe:tia_guide {"topic":"recipes"}, 'Recipe — generate the FAT/SAT I/O list'. - Prove the project matches what's versioned (a raw hash is NOT proof):
tia_guide {"topic":"recipes"}, 'Recipe — prove the project matches the versioned XML'.
Network lifecycle (subnets, PROFINET names, IO systems)
Read first (tia_subnet_get, tia_device_network, tia_io_systems), then run each write's dryRun (answered by
the serve, needs an open project). Order, PROFINET names, disconnectNodes: tia_guide {"topic":"recipes"}, 'Reference — network, audit and CAx how-to'.
- Refused, nothing changed:
tia_subnet_deleteof a non-empty subnet (409 subnet_not_empty);tia_io_system_connectacross subnets (409 cross_subnet_assignment:tia_network_connectthe device to that subnet first). 409 postcheck_failed: the write did not take effect as asked: re-read, never repeat blindly.
Libraries, HMI, CAx and PLC security
Reads are class R; every change is class M-off (offline, with dryRun) and reaches the CPU
only through a later tia_compile + human-gated tia_download (G3). Every file path is a
path ON THE SERVE HOST.
- Guarded PLC writes (
tia_tag_update,tia_constant_update,tia_constant_delete,tia_tagtable_delete,tia_block_group_delete,tia_ob_create,tia_block_compile): the serve answers theirdryRun(it needs an open project) with the guard verdict (name collision, default tag table, non-empty group, singleton OB). - Project library:
tia_library_mastercopies/tia_library_typesread it;tia_library_mastercopy_createturns a DEVICE into a master copy (a block cannot be a source);tia_device_from_mastercopyinherits PUT/GET, OPC UA license selection and HR mappings into a NEW station; regenerate its certificate;tia_block_from_mastercopyneeds one that holds PLC blocks. - Global libraries (in the TIA Portal session, not the project):
tia_global_libraries,tia_global_library_create/_open/_save/_close; save/close take the name fromtia_global_libraries(exact name first, then ignoring case). REFUSED, nothing saved or closed (404 not_found/409 conflict): a name that picks no single open USER library (unknown, read-only system/corporate, several matches ignoring case) and a save of areadWrite:falselibrary. Up to app 1.6.3 an unknown name can report success without saving or closing anything: checktia_global_libraries. - HMI:
tia_hmisandtia_hmi_screensread any HMI; screen files (tia_hmi_screen_export,tia_hmi_screens_import) work for WinCC Classic only, and the import OVERWRITES same-named screens. - CAx (AutomationML):
tia_cax_export/tia_cax_import(scope,optionvalues: recipes). Archive the project before an overwrite. A failed transfer is an error after app 1.6.3; on an older serve check the devices withtia_devices. - Error contracts by app version:
tia_guide {"topic":"recipes"}, 'Reference — global library and CAx error contracts (by app version)'. - PLC security:
tia_certificates/tia_certificate_template/tia_password_policyread;tia_certificate_import/_export/_delete,tia_password_policy_setandtia_block_protectchange the project. G6: a block or certificate password and the password-policy values come from a HUMAN — never invent, guess or reuse one; dryRun plans show a password as[redacted]. A CPU without the certificate manager or a policy service answers 409. - Multiuser:
tia_project_servers,tia_server_projectsread Project Servers;tia_local_session_openneeds NO open project (tia_project_close,tia_start). Nothing is ever checked in.
Recipes (runtime-verified)
Not copied here: Codex reads at most 32 KiB of AGENTS.md and cuts the rest without a word. Call
tia_guide {"topic":"recipes"} for the verified recipes (unlocking a freshly-created CPU, the in-place firmware
bump, Modbus TCP, S7 PUT/GET and OPC UA on the S7-1200, the scaffold order) before you need one.
The project-spec (input model)
A project-spec is ONE JSON document describing the whole project. Always run it
through the pipeline front door: tia_spec_validate (rung 0, pure) → tia_spec_plan
(dry) → tia_spec_apply (M-off, stops at gates).
tia_spec_validate checks the shape only in part (it does not run the JSON Schema; the spec-validate
skill adds it) and enforces: unique device/subnet/UDT/block/per-table tag names; every network node IP
inside the subnet CIDR; OrderNumber:<MLFB>/V<fw> with /V — never :V (Gd5); no STL/GRAPH on an
S7-1200; at most 8 SMs on an S7-1200 (its only module limit); and G5 — a spec with safety content
marked autonomous is REJECTED (F-logic is never autonomous).
Minimal example:
{
"project": { "name": "Line2", "directory": "C:\\TIA\\Line2" },
"conventions": {
"namingScheme": "plcopen",
"optimizedAccess": true,
"symbolicOnly": true,
"defaultLanguages": { "interlocks": "LAD", "algorithms": "SCL", "sequencers": "GRAPH" }
},
"devices": [
{
"name": "Line2_CPU",
"typeIdentifier": "OrderNumber:6ES7 511-1AK02-0AB0/V2.9",
"role": "cpu",
"family": "S7-1500"
}
],
"network": {
"subnet": { "type": "System:Subnet.Ethernet", "name": "PN_Line2", "cidr": "192.168.0.0/24" },
"nodes": [{ "device": "Line2_CPU", "ip": "192.168.0.1", "createIoSystem": true }]
},
"dataTypes": [
{
"name": "UDT_Motor",
"members": [
{ "name": "xStart", "dataType": "Bool", "comment": "Start command" },
{ "name": "rSpeed", "dataType": "Real", "comment": "Speed [%]" }
]
}
],
"tagTables": [{ "name": "IO", "purpose": "IO" }],
"tags": [{ "table": "IO", "name": "Conv01_Run", "dataType": "Bool", "address": "%Q0.0" }]
}The plan and tia_spec_apply neither import dataTypes nor author block logic: UDTs go in with
tia_types_import, logic with tia_source_put / tia_import_xml.
Resolve every concrete MLFB + firmware via tia_catalog before building — never guess
an order number. Project firmware must be ≤ the physical device's firmware.
<!-- tia-harness:end -->Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.
Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.