Consult this skill when deploying Ray clusters on Kubernetes via KubeRay, designing topology-aware placement for NVLink/TPU/InfiniBand hardware, configuring GCS high availability, building multi-region or multi-cloud Ray platforms, debugging training failures with the Ray History Server or platform events, or evaluating GPU observability stacks. Trigger on questions about rack-aware scheduling for GB200/GB300, TPU slice placement groups, NCCL hang detection, preemption handling, or KubeRay operator lifecycle. NOT for Ray Data pipeline design patterns (see ray-data-pipelines), Ray Serve routing logic, or general Kubernetes administration.

The file

We split this skill into the rules it gives an agent

2 rules. About 0 are common, 2 are distinctive, and 0 are very specific to this project.

  • ≈0

    Common · estimate

    Many files like this have a rule of this kind.

  • ≈2

    Distinctive · estimate

    This author's own choices. Worth a look.

  • 0

    Very specific

    Tied to their project's names, files or tools. Probably skip.

  • Common
  • Distinctive
  • Very specific
  1. Distinctive:

    No spare in rack → bundle left pending.

    line 123
  2. Distinctive:

    Before serving customers, stress-test every component: GPUs (multi-day workloads surfacing XID/remapping errors), CPU nodes, …

    line 277

≈ “Common” is an estimate: at least 1 in 5 of the 350,495 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.

Keep what fits and drop the rest. Your version, ready for your agents.
Files
SKILL.md

Ray on Kubernetes Infrastructure

The scheduling topology — not the cluster size — determines training throughput.

Production Ray-on-K8s deployments fail most often from three causes: topology-unaware placement fragmenting interconnects, opaque infrastructure failures hiding behind generic Python errors, and missing post-mortem observability for ephemeral clusters. The patterns below address all three, drawn from 13 infrastructure talks at Ray Summit 2026.


KubeRay Operator Architecture

KubeRay is the open-source Kubernetes operator for Ray, written in Go. It provides CRDs (RayCluster, RayJob, RayService, RayCronJob) to declaratively manage Ray clusters on Kubernetes.

Lifecycle

YearMilestone
2022–23ByteDance donates initial operator; generative AI drives adoption
2024Hardening: CRD maturity, scalability, 1.0 GA release
2025Open-source standard; deeper K8s primitive bridging
2026Co-engineering era: K8s workload API integration, topology strategies

Key CRDs

  • RayCluster: Head + worker group pods; autoscaler-managed
  • RayJob: Ephemeral cluster per job; auto-teardown on completion
  • RayService: Long-lived serving with zero-downtime rolling upgrades (beta in 1.7)
  • RayCronJob (1.7): Scheduled repetitive Ray jobs

KubeRay 1.6–1.7 Features

  • History Server (beta): Post-mortem dashboard for terminated clusters
  • K8s RBAC authentication: Native token auth via TokenReview + SubjectAccessReview APIs; works with OIDC/Entra ID
  • mTLS + network policies: Red Hat contribution for security compliance
  • Embedded RocksDB: LinkedIn contribution; GCS persistence without external Redis
  • In-place pod resizing (alpha): Autoscaler resizes running pods before adding new ones
  • K8s Workload API: Microsoft contribution; native gang scheduling via PodGroup objects without third-party schedulers
  • Ingress API integration: Microsoft contribution; customizable ingress behavior
  • Node label forwarding webhook (roadmap): Propagate K8s node labels → pods → Ray processes for topology strategy API
  • Selective node event forwarder (roadmap): Forward filtered node-level hardware events to Ray dashboard

Platform Integrations

  • GKE: Managed Ray operator add-on, node auto-provisioning, DRET networking for TPUs
  • AKS/Anyscale on Azure: ARM-native provisioning, Entra ID, workload identity, private networking
  • SageMaker HyperPod: Kueue integration, managed dev environments, tiered checkpointing
  • Anyscale KubeRay Connect (preview): Mutating webhook injects observability sidecars onto existing KubeRay CRDs; keeps KubeRay operator as reconciler

Topology-Aware Scheduling

The Core Problem

Standard schedulers treat accelerators as fungible. Requesting 64 GPUs may scatter them across 16 racks, losing 2.7× NVLink bandwidth and increasing fault exposure. For TPUs, cross-slice scheduling causes indefinite XLA hangs.

Hardware Topology Hierarchy

Data Center
 └─ Availability Zone
     └─ Scale Unit (InfiniBand)
         └─ Rack / NVLink Domain (GB200: 72 GPUs, GB300: 72 GPUs)
             └─ Compute Tray / Host (4 GPUs + 2 ARM CPUs + 4 ConnectX NICs)
                 └─ GPU

Network Fabrics

FabricScopeBandwidth (GB200)Notes
NVLink (intra-rack)Within NVLink domainHigh bandwidth (TB/s class)NVSwitch on back of rack
InfiniBand / RoCE (inter-rack)Across racks400 GB/s (GB200), 800 GB/s (GB300)Hierarchical; within-scale-unit faster than cross
Front-end EthernetStorage, SSH, managementVariesCongestion risk if workloads are front-end heavy
TPU ICIWithin TPU sliceDedicated optical2D/3D torus mesh; slice is indivisible
Data center networkAcross TPU slicesStandard DCNFor multi-slice training

NVLink Sharp

Offloads AllReduce to dedicated ASICs on NVSwitch. Benchmark: 920 GB/s vs 338 GB/s without (2.7× speedup on single rack). Ask providers if Sharp is enabled.

Decision Framework: When Topology Matters

WorkloadTopology Critical?Why
Tensor parallelism, expert parallelismYes — pack within NVLink domainHigh per-step data movement
Pipeline parallelism, data parallelismLess criticalLower cross-boundary data volume
Pre-training AllReduce at scaleYes — rack-aware placement14–30% throughput gain from bin-packing
RL weight transferYes — NVLink domainEnables on-policy training; faster weight sync
Batch inference / data processingUsually noEmbarrassingly parallel; interconnect not bottleneck
TPU SPMD workloadsAlways — slice atomicityXLA deadlocks if chips span slices

Ray Topology Strategy API (Ray 2.55+)

GPU Rack-Aware Scheduling

from ray.util.placement_group import placement_group

pg = placement_group(
    bundles=[{"GPU": 4}] * 16,       # 16 hosts × 4 GPUs = 64 GPUs
    strategy="STRICT_PACK",
    topology_strategy={
        "strategy": "STRICT_PACK",
        "topology": "rack"            # All bundles on same NVLink domain
    }
)
ray.get(pg.ready())

Fault tolerance is built-in:

  • Node fails in rack → reschedule to spare node in same rack
  • No spare in rack → bundle left pending; observable via state API
  • Entire rack fails → migrate all bundles to spare rack if available

NVIDIA Groot N1.7 benchmark: 512 GB300 GPUs, 8-rack topology-aware vs scattered → 14.4% throughput improvement (estimated 20–30% on GB200 due to lower inter-rack bandwidth).

TPU Slice Placement Groups (Ray 2.55+)

from ray.util.accelerators.tpu import SlicePlacementGroup, dispatch

# Reserve one v4-32 slice atomically
spg = SlicePlacementGroup(topology="2x2x4", version="v4")
ray.get(spg.ready())

# Execute SPMD task across all hosts in slice
results = dispatch(spg, my_tpu_task)
  • Multi-slice: SlicePlacementGroup(topology=..., num_slices=4) for pipeline parallelism
  • Dynamic sub-slicing: Carve geometrically valid sub-slices from pre-provisioned large slices at runtime; eliminates capacity stranding
  • Elastic training: min_workers / max_workers range; job continues on available slices

Multi-Host Gang Scheduling on KubeRay

For TPU multi-host groups, set numOfHosts in worker group spec. GKE mutating webhook injects pod affinity/anti-affinity rules + JAX/PyTorch environment variables. Pods are atomically gang-scheduled to same node pool.

For K8s native gang scheduling without third-party schedulers, use Kubernetes Workload API PodGroup objects (KubeRay 1.6 + K8s 1.36).


Ray Core Reliability

GCS High Availability

BackendCharacteristics
Redis (existing)Network-based; separate lifecycle; Redis itself can be SPOF
Embedded RocksDB (new)Local disk ops; lifecycle tied to Ray head; no external dependency
Active-passive GCS (in progress)K8s lease-based leader election; passive acquires leadership on failure; workers use same K8s head service endpoint

Cgroup-Based Resource Isolation

Separates Ray system processes from application workloads using Linux cgroups. Benchmarks show zero OOM kills from resource contention, zero node failures, and predictable completion times.

Scalability Improvements (Ray 2.55–2.58)

  • 1.6× task throughput: Fewer RPCs, less lock contention, faster lightweight op paths
  • 300× faster placement group creation: Merged resource sync broadcasts; 10K-node PG from 45 min → 9 seconds
  • 40K actors on 10K nodes: Combined PG + actor scheduling improvements
  • Task event offloading: High-volume events offloaded from GCS to reduce control plane pressure

Preemption Handling

info = ray.train.get_preemption_info()
if info is not None:
    # info.deadline — timestamp when node will be reclaimed
    # info.affected_ranks — which workers will be lost
    save_checkpoint()  # JIT checkpoint before deadline
  • GKE TPU: ~30 seconds warning
  • AWS spot: ~120 seconds warning
  • Qwen3-8B on 4× H100 spot: JIT checkpointing reduced recomputed steps from 672 → 4 (100× less waste), 60% cheaper than on-demand (vs 50% with periodic-only checkpointing)

NCCL Hang Detection (Ray Train, coming soon)

  • Background thread polls NVIDIA RAS (Reliability, Availability, Serviceability) collective counters
  • Detects count mismatches before PyTorch 30-minute timeout
  • Auto-saves diagnostics on first failure: RAS reports, per-rank stack traces, PyTorch Flight Recorder, nvidia-smi per node
  • Zero performance overhead (runs on separate thread)

Observability Stack

Layer 1: Ray Dashboard + Platform Events (Ray 2.58+)

K8s events streamed into Ray Dashboard via lightweight background pull in Ray head process. Feature gate: RAY_DASHBOARD_ENABLE_PLATFORM_EVENTS=true.

What surfaces:

  • Pod lifecycle: image pull latency, OOMKilled, eviction, rescheduling
  • Ray CR events: RayCluster, RayJob, RayService state transitions
  • Node hardware faults (via selective event forwarder): XID errors, GPU ECC faults

Architecture:

  • Provider-agnostic Protobuf schema (extensible to Slurm, other clouds)
  • Client-side label filtering: only pods belonging to active Ray cluster
  • Bounded LRU ring buffer: capped memory even in noisy clusters
  • Events exported as structured JSON lines; compatible with Fluentbit/Vector/Promtail → Grafana/CloudWatch/Datadog

Layer 2: History Server (KubeRay 1.7 beta)

Post-mortem replay engine for ephemeral clusters. Zero idle compute cost.

Architecture:

  • Collector (sidecar): Uploads Ray logs from shared tmpdir + events via HTTP to object storage. Handles graceful shutdown, session transitions, and crash recovery.
  • Server (stateless deployment): On-demand loading with bounded LRU cache. Horizontally scalable. Serves standard Ray Dashboard APIs.
  • Supports GCS, S3, Azure Blob as backends.

Collaboration: Google + Anyscale + Alibaba; 100+ PRs.

Layer 3: GPU Observability (Datadog / External)

Job-level diagnosis beyond device metrics:

  • Straggler detection: Identify slow rank + deviation from peers per training step
  • Continuous tracing (<2% overhead): Correlate CPU→GPU execution; link back to Python call sites
  • Topology visualization: Group affected workers by shared physical infrastructure (host, rack, GPU link)
  • Root cause analysis: Connect MFU/step-time changes to hardware faults (ECC, XID, NVLink recovery events)

Meta Llama 3 reference: ~1 failure every 3 hours on 16K GPUs; 1% efficiency loss = $4.3M/year on $36M/month fleet.

Layer 4: Ray Train Data Ingest Observability

Live dashboard showing:

  • Average batch cycle breakdown (exposed data loading time vs training)
  • Per-stage latency: read → transform → collate → transfer → train
  • Per-rank breakdown to identify stragglers
  • Pipeline delivery throughput vs median worker ingest throughput
  • Grafana panels for lifetime metrics; open-source with custom Prometheus backend

Multi-Region / Multi-Cloud Deployment

Notion Pattern: Environment-Isolated Anyscale Clouds

Problem: Single Anyscale cloud per region with shared IAM roles; dev/prod co-mingled; no real data isolation despite multi-region labels.

Solution: Separate Anyscale cloud per environment per region (8 clouds for US/EU/JP/KR × dev/prod). Each cloud gets scoped IAM role pair (control plane + cluster). Two-phase Terraform registration locks permissions to cloud ID.

Key lessons:

  1. Multi-region without permission isolation is not truly multi-region
  2. Real isolation boundary is at IAM/networking/data access level, not logical labels
  3. Terraform provider adoption is a two-way relationship — import path only tested because Notion exercised it

Anyscale Scheduler (Multi-Cloud)

Unified interface for priority-aware queuing and cross-region capacity search. Kubernetes-native manifest generation. Same compute config works across any registered region/cluster/hyperscaler.

SageMaker HyperPod Multi-Tenant Pattern

Namespace-based isolation per team. Kueue provides:

  • Priority-based admission (production inference > weekend experiments)
  • Fair-share with floor guarantees + idle capacity lending between teams
  • Gang admission for training (all-or-nothing pod scheduling)
  • Elastic admission (scale up without losing Ray head state)

Hardware Topology Quick Reference

NScale Validation Process

Before serving customers, stress-test every component: GPUs (multi-day workloads surfacing XID/remapping errors), CPU nodes, backend/frontend fabric (port flapping, cable verification), storage. Bake optimal configs (NCCL env vars, PCIe settings, topology-aware Linux services) into images. NVIDIA Exemplar status validates top performance across model families.

GB200/GB300 Key Facts

  • 18 compute trays × 4 GPUs = 72 GPUs per rack
  • NVLink domain = full rack (NVL72); roadmap to NVL576 (8 racks)
  • NVLink Sharp: AllReduce offloaded to switch ASICs
  • Fault tolerance: node-level (spare in rack) vs rack-level (spare rack)
  • Each compute tray: 4 Blackwell Ultra GPUs + 2 ARM Grace CPUs + ConnectX NICs

TPU Key Facts

  • Slices: indivisible hardware units; chips connected via ICI (optical 2D/3D torus)
  • Scheduling: must land all workers on same contiguous physical mesh
  • TPU v7: 2×2×2 slice = 8 chips across 2 hosts
  • JAX: host-centric (1 process per VM); PyTorch: device-centric (1 process per chip)
  • Sub-slicing: carve geometrically valid partitions from large slices at runtime
  • GKE bootstraps XLA env vars via mutating admission webhook

Switches Are Computers

InfiniBand and NVSwitch support in-network compute (Sharp). AllReduce aggregation happens at the switch instead of node round-trips. Ask if Sharp is enabled.

Download now (ZIP)

Does it work?

Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.

No reviews yet

People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.

  • It worked
  • Partly
  • It didn't
What did you use it for? e.g. Reviewing pull requests in a Rails app

Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.

Your trail

Files you open will collect here, so you can find them again.

Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.

Now do this for your own.

Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.