  1. Distinctive:

    Place the listening position about 38 percent of room length from the front wall (common starting point.

    line 34
  2. Distinctive:

    Keep monitors at least 30 to 60 cm from walls.

    line 35
  3. Distinctive:

    Use decouplers (foam pads or stands) to reduce desk vibration.

    line 36
  4. Distinctive:

    Check mixes on headphones, earbuds, a phone, the car.

    line 37
  5. Distinctive:

    Avoid: egg-crate foam as treatment (thin, low-frequency ineffective), fully dead rooms, covering only high-mid.

    line 54
  6. Distinctive:

    Read: dips from boundary cancellation cannot be fixed by EQ.

    line 59
  7. Distinctive:

    Ask room size (L x W x H) and speaker/desk setup only when needed.

    line 66

≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.

Keep what fits and drop the rest. Your version, ready for your agents.
Files
SKILL.md

Sound engineer and room acoustics

Basis: standard audio engineering and acoustics (physics below is exact; product claims are not made). Mark anything uncertain. For Linux-specific audio daemons use linux-audio-production.

Troubleshooting method (one step at a time)

  1. Define: no sound / crackle / latency / noise / hum / level / one channel / feedback.
  2. Isolate the chain: source > cable > interface input > driver > DAW track > bus > output > cable > monitors.
  3. Change one thing, test, record result. Swap cable, then port, then device.
  4. Reproduce with a simple test (sine, pink noise, a known file). Give the next single step, not the whole list.

Common problems

  • Clicks/pops/dropouts: buffer too small, CPU or USB issues, wrong sample rate on the device vs DAW, power saving on USB, plugin overload; raise buffer to 256 or 512 to test, check xruns.
  • Latency: round-trip = buffer plus converter plus driver. Monitor through the interface direct-monitor for tracking. Typical targets: tracking 64 to 128 samples at 48 kHz, mixing 512 to 1024.
  • Hum (50/60 Hz): ground loop; use balanced cables, same power strip, DI box or isolator, lift ground only if it is safe (never remove a safety earth).
  • Hiss: too low a source level raised later; gain stage hotter at the source, check the noisy cable/preamp.
  • Distortion: clipping at the preamp, converter or plugin; target peaks around -12 to -6 dBFS while tracking (24-bit), mix with headroom.
  • One channel only: mono/stereo cable (TS vs TRS), pan, routing, mono sum, phase cancellation.
  • Phase issues: polarity flip, align time, check mono compatibility; low end must hold in mono.
  • Feedback: monitors and mic open; reduce gain, mute mic, distance.
  • Level mismatch: consumer (-10 dBV) vs pro (+4 dBu) outputs; pad or trim.
  • Digital sync: one clock master (word clock or ADAT/SPDIF auto), mismatch gives clicks.

Gain staging

Digital 0 dBFS is a ceiling, not a target. Set the monitor volume once, then adjust sources rather than the speaker. Common calibration (UNVERIFIED this session, widely cited): pink noise at -20 dBFS RMS per speaker reads 85 dB SPL(C) in film practice (SMPTE RP 200) and about 83 dB in small rooms (K-20 style). Check with an SPL meter before relying on it.

Monitoring

  • Equilateral triangle: monitors and head form 60 degrees; tweeters at ear height, toe-in aimed at ears.
  • Place the listening position about 38 percent of room length from the front wall (common starting point; avoid the exact center of the room).
  • Keep monitors at least 30 to 60 cm from walls; if close, use the speaker's boundary/room-compensation switch.
  • Use decouplers (foam pads or stands) to reduce desk vibration; subwoofer needs measurement for crossover, level and phase.
  • Check mixes on headphones, earbuds, a phone, the car; use references at matched loudness.

Room acoustics: key physics (exact)

  • Speed of sound c ≈ 343 m/s at 20 C.
  • Axial room modes: f = c / (2 L) for each dimension; harmonics at n times that. Example: 4 m wall gives about 43 Hz, 86 Hz, 129 Hz.
  • Wavelength = c / f. A porous absorber works best when its depth is a good fraction (about 1/4) of the wavelength, so 100 Hz needs about 86 cm of material in free air (less with an air gap behind it; the gap adds effective depth).
  • Schroeder frequency Fs ≈ 2000 sqrt(RT60 / V) (V in m3): below it the room is modal (use bass traps/EQ), above it diffusion/absorption.
  • RT60 target for a small control room: about 0.2 to 0.4 s, fairly flat across frequency (typical guidance; room size matters).
  • Rule of thumb for early reflections: treat the first reflection points on side walls, ceiling and front wall behind the monitors.

Treatment priority (cheapest impact first)

  1. Speaker/listener placement and symmetry.
  2. Corner bass traps (thick porous, e.g. mineral wool/rigid fiberglass, or membrane traps for deep targets).
  3. First reflection points: side walls, ceiling cloud, front wall.
  4. Rear wall: diffusion or absorption depending on distance (at least about 1 to 2 m is better for diffusion).
  5. Floor/rug and desk reflection control.
  6. Then EQ/measurement-based room correction (use it for peaks, do not boost nulls). Avoid: egg-crate foam as treatment (thin, low-frequency ineffective), fully dead rooms, covering only high-mid. Soundproofing (stopping sound leaving the room) is different from treatment: needs mass, decoupling and sealing (gaps, doors, HVAC); absorption does not block sound.

Measurement

  • Software like REW (Room EQ Wizard) with a measurement mic (e.g. calibrated USB/XLR omni) gives frequency response, waterfall/decay, RT60 and modal peaks. Take several positions around the head and average.
  • Read: dips from boundary cancellation cannot be fixed by EQ; fix by moving speakers/listener or adding absorption. Peaks can be reduced by EQ.
  • Re-measure after each change; keep a log.

Hardware routing basics

Balanced XLR/TRS for monitors; keep unbalanced short; analog and digital cables away from mains; interface to speakers direct, no daisy chain; use a power conditioner only as a convenience (it does not fix grounding). USB: avoid hubs, use the rear ports; check cable and device sample rate agree. For hardware synths: each stereo pair to its own input or via mixer; MIDI over USB or DIN; clock master set once.

Style

Ask room size (L x W x H) and speaker/desk setup only when needed. Give one step at a time; give formulas with the numbers worked out. Say what is a rule of thumb vs physics. Recommend measuring rather than guessing.

Download now (ZIP)

Does it work?

Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.

No reviews yet

People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.

  • It worked
  • Partly
  • It didn't
What did you use it for? e.g. Reviewing pull requests in a Rails app

Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.

Your trail

Files you open will collect here, so you can find them again.

Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.

Now do this for your own.

Bring your CLAUDE.md, AGENTS.md or skills. agentleFS shows which of your rules are common, which are yours and which only fit one project, and keeps one version your agents read everywhere.