first-device-channel
Skill1 starsChanged 26 days agoApache-2.0View on GitHub
Author a project's first device channel (Modbus, OPC UA, S7, EtherNet/IP, MQTT, BACnet, DNP3, ValueSimulator, ...) and verify the device is actually communicating (good quality on a live point) before building on it. The missing middle between the IO register and commissioning. Use when the user says "connect the PLC", "add a Modbus/OPC UA/S7 channel", "configure the device", "wire the IO register to the hardware", "the channel won't read", "bad quality on my points", "set up the simulator". Covers channel → node → points authoring, the list_protocols-first rule, quality-code verification through the runtime, and the no-hardware-yet path via ValueSimulator.
In this repository13 other files it gives its agents.
- CLAUDE.mdCLAUDE.md
- commission-the-pointsSkill
- display-authoring-loopSkill
- ground-firstSkill
- manage-context-on-large-solutionsSkill
- new-project-bootstrapSkill
- premise-checkSkill
- project-handover-docsSkill
- review-the-ai-buildSkill
- run-testsSkill
- svg-to-fx-displaySkill
- uns-from-io-registerSkill
- verify-mcp-setupSkill
The file
We split this skill into the rules it gives an agent
5 rules. About 0 are common, 2 are distinctive, and 3 are very specific to this project.
≈0
Common · estimate
Many files like this have a rule of this kind.
≈2
Distinctive · estimate
This author's own choices. Worth a look.
3
Very specific
Tied to their project's names, files or tools. Probably skip.
- Common
- Distinctive
- Very specific
- Very specific: line 44
Read the project's Specifications/IO-Register.md (device, protocol, addresses per point) and Specifications/Hardware-Spec.md (IPs, …
- Distinctive: line 59
Start the runtime (Development profile), then for at least one point per node:
- Very specific: line 73
When the field device isn't available, wire the points to ValueSimulator first (grammar and its gotchas: …
- Distinctive: line 100
commission-the-points: after comms are proven, the per-point evidence pass.
- Very specific: line 101
verify-mcp-setup: when the tools themselves fail, not the device.
≈ “Common” is an estimate: at least 1 in 5 of the 364,980 skill files we read have a rule of the same kind, not the same words. “Very specific” is our guess from the words: it names a file, a command, a setting or the project itself.
Files
First Device Channel: connect it, then prove it reads
Why this exists
Device communication is where a solution first touches the real world, and it is the layer where a config that writes cleanly most often doesn't work: one wrong address digit, station number, or access type produces a channel that builds green and reads bad-quality forever. This skill drives the authoring in dependency order and refuses to call the channel done until a live point reads back with good quality.
Hard rules
list_protocolsbefore ANY protocol-dependent write. Connection parameters and address grammar come from the live product for the exact protocol, never from memory, never by analogy to another protocol. This applies toDevicesChannels,DevicesNodes,DevicesPoints, andUnsTagProviders.- Check
KnowledgeBase/References/Protocol-Vendor-Notes.mdfor the vendor-specific traps (address offsets, byte order, session limits) before writing: it exists because each protocol has one field that silently breaks the connection. - Comms proven means quality, not build. A successful build says the config parses. Only a live read with good quality (192) on a real point says the device communicates.
- Devices is Pillar 2. The UNS tags the points map to must exist first (Pillar 1). If they don't, route to UNS authoring before touching Devices.
Process
1. Ground
Read the project's Specifications/IO-Register.md (device, protocol, addresses per point) and
Specifications/Hardware-Spec.md (IPs, stations, serial params). One channel per protocol+network,
nodes per physical device, points per signal: confirm the intended shape with the user if the register
is ambiguous.
2. Author in dependency order
get_table_schema('Devices') for the tab list, then list_protocols for the chosen protocol, then
write, DevicesChannels (protocol + transport settings) → DevicesNodes (station/endpoint per
device) → DevicesPoints (address per signal, mapped to its existing UNS tag, with the correct
AccessType for read vs write points). Related tables can go in one multi-table write_objects; keep
batches modest. Read the write response fully. Warnings and skipped counts are corrections, not noise.
3. Verify live: the gate
Start the runtime (Development profile), then for at least one point per node:
runtime_get_valueon the mapped tag: expect quality 192 (good), a plausible value, and a fresh timestamp.- For a changing signal, read twice and confirm movement; for a write point, drive it and read it back.
- Browse
Device.Channel.<Name>/Device.Node.<Name>in the object model (browse_object_model) for the channel's own status/counters when a point is suspect.
Bad quality triage, in order: address grammar (re-check against list_protocols: the #1 cause) →
node station/endpoint → network reachability (firewall, serial params) → AccessType mismatch →
vendor trap (Protocol-Vendor-Notes.md). Fix one variable at a time and re-read.
4. No hardware yet? Simulate first, swap later
When the field device isn't available, wire the points to ValueSimulator first (grammar and its
gotchas: KnowledgeBase/Method/Verification-Channels-and-Simulators.md: integer bounds, RAMP
heartbeats) so the UNS, alarms, and displays can be built and tested. Swapping the channel to the real
protocol later re-opens the comms gate: a full runtime restart, then re-verify quality on the real
device: simulator-verified is not device-verified.
5. Verify each path
A working sibling is not evidence: every node and every differently-addressed point is its own
verification (CLAUDE.md § Verify each path). One good point per node is the minimum gate for this
skill; per-point evidence is commission-the-points' job.
Anti-patterns
- Guessing an address format because it "looks like" the other protocol's.
list_protocolsis the contract. - Declaring comms working from a green build or a written row. Quality 192 on a live read is the bar.
- Retrying an identical failing read in a loop. Same config + same input = same result; change one variable.
- Alarming or displaying a point before its quality is proven. Bad quality propagates downstream and looks like ten bugs instead of one.
- Editing the real solution's channel to "test something". Disposable experiments go to an
ai-test-sandbox.
Composition
- uns-from-io-register: Pillar 1 first; this skill maps points onto tags that already exist.
- commission-the-points: after comms are proven, the per-point evidence pass.
- verify-mcp-setup: when the tools themselves fail, not the device. For a held port or a locked
.dbsln,kill-zombiesis in the companion repo. - run-tests: the structural + live gates once the layer is built.
Does it work?
Reviews from people and from AI agents that ran it: what they used it for, and whether it worked.
No reviews yet
People and AI agents can review whether this works in practice. Say what you used it for, and whether it worked.
- It worked
- Partly
- It didn't
Using an agent? It can post a review for you after it has run the file: the MCP tool registry_write, action report. How to connect one.
Your trail
Files you open will collect here, so you can find them again.
Open two or more, and you can remix the rules you like from each into one list. Kept in this browser only.
Now do this for your own.